- The recall of the JOB is inactive when navigating in the welding cycle or one of the two menus,
* A JOB is amended by action on the interface (welding settings, JOB recall...), the welding is authorised using the new settings entered. If a JOB
recall is done, then the first JOB of the list if recalled.
CHAIN « Chn » :
The chain is a recall mode for complex JOBs (50 max) and only available when using the TIG STD and PULSE processes (all the JOBs defined in 2T
are forced in 4T) :
- Outside . On reaching the last item in the list, the selection goes back to the first item.
- Welding is activated by pressing the top button for 0.5s where in the standard mode, it is activated by simply pressing this button.
- During welding, briefly releasing the buttons (less than 0.5s) allow to recall a consecutive and defined JOB number, also called sequence and starting
from the JOB previously recalled when not welding.
Access to this mode is done by pressing the menu
mode by entering a number of JOBS part of its sequence. At least 2 JOBS must be saved prior to that.
Spot welding jobs (SPOT, TACK), are no longer part of the list of saved JOBS (they are transparent).
Ex : if the JOBS 1 to 50 have been created and the user has entered the number 3 in the sub-menu « C H n » :
- On activation of the sub-mode and when not welding, briefly releasing the torch button allows to show the JOBS one by one from
the 1st to the 50th (going back to the beginning when JOB 100 is reached). Here the user displays the JOBS and chooses the 10.
- Pressing the button for over 0.5s allows to start welding with JOB 10 (first of the sequence) and briefly releasing it loads JOB 11
and then JOB 12 (these 3 JOBS make the sequence).
- When the welding stops, the JOB 10 is loaded and displayed on the interface (this saves the user the task of having to show all
the JOBS again).
>0.5s
The MMI interface has these features:
- The JOB is displayed permanently as well as the settings (TIG LIFT/HF, 4T, Pulse...).
- The cycle is accessible and amendable (the JOB can be changed*),
- The menus are accessible and are amendable. Ex :
• JOB 5, amendable, SAVE IN / JOB 5, the JOB is saved and amended in line with the new settings entered.
• JOB 5, amendable, SAVE IN / JOB inexistent, it will be taken into account in the current q.L if and only if this new JOB X is below the number of
the JOB entered.
- When currently browsing the welding cycle or one of the two menus, the JOB recall function is disabled.
- During welding, when recalling a JOB of the sequence, the screen displays JOB X for 1s.
* A JOB is changed by action on the interface without saving, the welding is authorised without taking into account the modifications on the JOB
recalled.
COMMAND BUTTON(S) CONNECTOR
DB
P
L
34
Cabling diagram for the SRL18 torch.
TITAN 400 DC
, then the sub-menu
<0.5s
<0.5s
1
P
5
torch
2
4
L
DB
torch
2
torch
3
. Deactivated by default
>0.5s
4
3
5
2
6
1
NC
EN
, the user activates this
DB torch
3
4
L torch
2
2
DB + P
5
torch
1
Electric diagram according to torch type.