Extended Operation; Control Options During Voice Calls - Telecom Behnke 20 Serie Instructions

Portiers téléphoniques a / b
Masquer les pouces Voir aussi pour 20 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Manual Door intercom devices a / b Series 20 / 30 / 50
GB
GB

Extended Operation

extended operation
7.

7.1. Control options during voice calls

During voice calls, Behnke intercom stations offer several control options to be activated using a
telephone with DTMF dialling:
Entry
Activation
code #
## x
##* Security
code 0
##* Security
code 1
##* Security
code 2
###
*#
**
*0
63
Function
Activate the relay
In order for a relay to be activated via an activation code, the relay operations
mode and the activation interval and, of course, the activation code need to be
set accordingly.
Set volume to x (x=0 to 9)
Volume settings apply to the current connection only. In case the volume is to be
changed permanently, please perform configuration steps 06 and 988.
Automated acoustic settings (without additional amplifier) (from V1.51 or later)
cf. following section
Automated acoustic settings (with additional amplifier) (from V1.51 or later)
cf. following section
Automated acoustic settings (keep mode) (from V1.51 or later) cf. following
section
Play voice message (from V1.30 or later)
The preset voice message for this setting will be played.
Hang-up (from V1.34 or later, this function can be set using configurations step
9918)
Enter the set-up mode (subsequently enter the security code)
Switch from operation with to operation without additional amplifier and back-
wards
1x ok beep ▸ indicates operation without additional amplifier
2x ok beeps ▸ indicates operation with additional amplifier
www.behnke-online.com