Manual Door intercom devices a / b Series 20 / 30 / 50
GB
GB
Configuration and Set-up
Code Parameter
21
Telephone number for button 1
22
Telephone number for button 2
23
Telephone number for button 3 (only Series 20)
:
:
28
Telephone number for button 8 (only Series 20)
29
Telephone number for button
Telephone numbers contain cyphers only and hold a maximum of 20
digits. When entering a telephone number, you may use the following
special characters (cf. chapter on programming):
*0 = dial *
*1 = dial #
*2 = Pause 2 seconds
*3 = Wait for dial tone
With version 1.30 or later:
*4x
x=0
x=1
x=2
x=3
x=4
x=5
17>0)
x=6
step17>0)
x=7
step 17>0)
x=8
step 17>0)
x=9
been defined)
*5 x
*0
*6x
*7x
57
on the number keypad (only Series 20)
Condition
Always
when timetable 1 is valid (only sensible with a clock-module)
when timetable 2 is valid (only sensible with a clock-module)
when timetable 1 is invalid (only sensible with a clock-module)
when timetable 2 is invalid (only sensible with a clock-module)
in case of technical alert (only sensible for configurations step
in case of no technical alert (only sensible for configurations
in case of no technical alert (only sensible for configurations
in case alarm input inactive (only sensible for configurations
any other case (only sensible if a different *4x condition has
Play voice message no. x (only sensible with a voice messages
module)
Play signal sequence
Display text no. x (only sensible with a display module in use)
Activate relays (1=Relay 1, 2=Relay 2, 3=Relays 1&2)
Confirmation
#
#
#
:
#
#
www.behnke-online.com