Overview Of The Rapid Shutdown Box Connection Area; Exterior View - SMA RSB-2S-US-10 Manuel D'installation

Rapid shutdown system
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SMA Solar Technology America LLC
6.2
Overview of the Rapid Shutdown Box Connection
Area
6.2.1

Exterior View

A
B
Figure 6 : Exterior view of the Rapid Shutdown Box
Position
Designation
A
DC connection for the input strings 1 and 2, channel A
B
DC connection for the input strings 3 and 4, channel B
C
Connection point for the equipment grounding conductor
D
Enclosure opening for the Rapid Shutdown Controller conductors and where
necessary for the conductors of an additional Rapid Shutdown Box (for con-
duits of trade size 16 mm (0.5 in))
E
Enclosure opening for maximum 2 output strings* and where necessary for
the conductors of the Rapid Shutdown Controller (for conduits of the trade
size 21 mm (0.75 in))
* The input strings 1 and 2 (channel A) as well as 3 and 4 (channel B) are connected in parallel inside
the Rapid Shutdown Box.
Installation Manual
6 Electrical Connection
C
RSS-US-IA-xx-14
D
E
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rsc-1x-us-10

Table des Matières