9.2.10 Digital I/O Page

From menu entry Digital I/O it is possible to configure
the digital channels available in the device. What
follows is a brief description of the configurable
parameters for each digital input.
• Alarm ID: Field used to select the desired digital
input.
• Type: It indicates the default state of the digital
input.
To check correct operation of the alarms, a dot will
appear on the web page. The dot will be green
in normal conditions and red when an alarm is
detected.
Fig. 48

9.2.11 Wiper

Do not use the wiper if the outside
temperature is below 0°C or in case of ice.
The integrated wiper does not interfere with the
viewing range of the installed camera.

9.2.12 Washer page

From the menu, it is possible to configure the device
wash system functions.
Fig. 49
MNVCMPXHD_1801_EN

9.2.13 Encoder Parameters page

In the Encoder Settings menu, it is possible to
configure up to 4 video flows of the device. The first
flow must be compressed with the algorithm H.264/
AVC while the others can alternatively use MJPEG
coding. For all the flows, you can set the video size,
the frame rate, use of the rate controller and the
I-Frame Interval (GOP size).
The OSD section allows configuration of the On
Screen Display (OSD) with the possibility of setting
a title for the video before compression. Lastly,
it is possible to configure the IPv4 address for
configuration of multicast video streaming. Editing
this setting will cause the device to restart.
Fig. 50