9
Disposal of Cleaning / Servicing Substances
Disposal of any such substances must be in accordance with all applicable local and
national regulations, directives and laws.
Warning
Pay special attention to all processing specifications and warnings issued by the
manufacturer of spraying and cleaning media. The improper disposal of any toxic
waste material represents a serious thread to to environment, i.e. to the health of
mankind and animal life.
10
Specification Data
Weight:
Connections:
Atomizing Air
Control Air
Material Inlet
Pressure Ranges:
Atomizing Air Pressure
Control Air Pressure
Material Pressure
max. Operating
Temperature
of Spray Gun
Sound Level
(measured at a distance
of 1 m from the spray gun)
Air Consumption:
1 bar Atomizing Air Input
2 bar Atomizing Air Input
3 bar Atomizing Air Input
4 bar Atomizing Air Input
5 bar Atomizing Air Input
6 bar Atomizing Air Input
Right to effect technical changes reserved.
500 g
G 1/8"
M 5
G 1/8"
see table
max. 6 bar
max. 6 bar
80° C
83 dB(A)
20 l / min.
30 l / min.
40 l / min.
50 l / min.
60 l / min.
80 l / min.
38