10 Troubleshooting
PROBLEM
GB
Pilot will not light
Pilot will not stay on
Burner will not light
Any changes or repairs to the unit must be performed by a qualified person.
Since the development of the produced equipment is progressing steadily, it may
happen that your product is minimally different from that described.
Possible Cause
– Gas valve may be OFF
– Tank fuel empty
– Opening blocked
– Air in supply system
– Loose connections
– Debris around pilot
– Loose connections
– Thermocouple damaged
– Gas leak in line
– Lack of fuel pressure
– Pressure is too low
– Opening blocked
– Control not turned on
– Thermocouple damaged
– Pilot light assembly bent
– Not in correct location
58
Solution
– Turn the gas valve ON
– Refil LPG tank
– Clean opening
– Remove air from lines
– Check all fittings
– Clean dirty area
– Tighten connections
– Replace thermocouple
– Replace line
– Tank nearly empty. Refill LPG tank
– Tank nearly empty. Refill LPG tank
– Clean the opening
– Turn control to ON
– Replace thermocouple
– Place pilot properly
– Position properly and tetry