DK50 2V/50
DK50 2x2V/110
Condensate drain
Compressors
Draining the condensate from the pressure vessel is
recommended during regular operation. Switch off the
compressor at the mains. Reduce air pressure in the
device to max. 1 bar by releasing air via a connected
device. Install the hose from the basic package into the
drain valve. Put the vessel under the hose and release
the condensate from the tank by opening the release
valve (1).
Carefully and slowly open the drain valve. Quickly opening the drain valve is
accompanied by a loud sound and uncontrollable stream of accumulated
condensate.
Compressors without a dryer may be equipped with the Automatic
Condensate Drain to allow the condensate to drain without operator
intervention (see chap. 8.2.).
Compressors with air dryer (Fig. 15)
Condensate from compressors with air dryers is automatically drained into
a condensate collection vessel. The vessel must be drained regularly.
Monitor the level in the vessel using the 1 l or 2 l markings (depending on the
volume of the vessel), and empty at least once a day. The vessel may overflow if
the condensate is not drained out of the vessel at the defined interval.
Risk of slipping on a wet floor in case of the condensatecollection vessel
overflow.
THE FOLLOWING IS REQUIRED BEFORE ANY FOLLOW-UP CHECKS
Compressors with cabinet - release the door lock and open the cabinet door.
Safety valve check
When the compressor is operated for the first time, make sure that the
safety valve is working properly. Turn the screw (2) on the safety
valve (1) several rotations to the left until the safety valve releases air.
Let the safety valve vent for only a few seconds. Turn the screw (2) to
the right until it seats, closing the valve.