PNEUMATIC CONNECTIONS
Connecting to the compressed air outlet
Route the pressure line from the compressed air outlet (1) on the
compressor to the device.
Route the pressure hose through the opening in the rear wall of the
cabinet for cabinet-mounted compressors.
Connecting the cabinet pressure gauge to the compressor
Remove the threaded plug (1) from the pneumatic block on the compressor.
Connect the cabinet pressure gauge hose (3) to the threaded fitting (2).
Fig.8
DK50 2V/50S
DK50 2V/50S/M
Connecting the condensate vessel
Connect the drain hose (1) to the condensate vessel on compressors with dryers.
Route the hose (1) through the opening in the rear wall of the cabinet for compressor models
with a dryer and connect it to the vessel.
NP-DK50 2V 50, 2x2V 110-27_12-2021-MD
-32-
DK50 2V/50
DK50 2x2V/110
1
DK50 2x2V/110S
DK50 2x2V/110S/M
Fig. 7
12/2021