Draining Tanks; Draining Recovery Tank; Draining Solution Tank; Charging Batteries - Nobles Speed Scrub 2001HD Opérateur Manuel Et Liste Des Piéces

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DRAINING TANKS

The recovery tank should be drained and cleaned out
after every use. The solution tank should be cleaned
out periodically to remove any corrosion.
Transport the machine to a draining site, turn the
machine off and follow the draining instructions below:
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.

DRAINING RECOVERY TANK

1. Remove the recovery tank drain hose cap by
turning it counter--clockwise and drain the tank.
To completely drain recovery tank, hinge open
tank sideways and flip up tank support stand to
rest tank on (Figure 24).
NOTE: When using a bucket to drain the machine, do
not use the same bucket to fill the solution tank.
2. Rinse out recovery tank after each use. This will
prevent a foul odor buildup. Use a hose to rinse
out the recovery tank. Be careful not to spray
water into the float shut--off screen.
3. Remove and clean the float shut--off screen
located in the recovery tank (Figure 25).
Speed Scrub 2001HD (09- -04)
FIG. 24
FIG. 25

DRAINING SOLUTION TANK

1. To drain any remaining water from the solution
tank, pull the solution tank level/drain hose off the
hose fitting as shown (Figure 26).
2. Rinse out solution tank and solution flow system
with clean water after each use. This will prevent
clogging due to chemical buildup. Use solution
tank level/drain hose to drain solution tank.
3. Reconnect hose to hose barb. Be certain hose is
completely pushed onto hose barb.

CHARGING BATTERIES

ATTENTION: To prolong the life of the batteries
and to provide optimum machine performance,
ONLY recharge the batteries after a total of 30
minutes of use or more. Do not leave batteries
discharged for lengthy periods.
The following charging instructions are intended for
battery chargers supplied with the machine. Only use
a battery charger with the following specifications to
prevent battery damage.
BATTERY CHARGER SPECIFICATIONS:
S
CHARGER TYPE: FOR LEAD ACID BATTERIES
S
OUTPUT VOLTAGE -- 24 VOLTS
S
OUTPUT CURRENT -- 25 AMPS
S
AUTOMATIC SHUT--OFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
1. Transport machine to a well ventilated area for
charging.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
OPERATION
FIG. 26
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Speed scrub 2001hd completeSpeed scrub 2001hd fastSpeed scrub 2001hd fast complete612214612086614364 ... Afficher tout

Table des Matières