OPERATION

DRAINING TANKS

The recovery tank should be drained and cleaned out
after every use. The solution tank should be cleaned
out periodically to remove any corrosion.
Transport the machine to a draining site, turn the key
off and follow the draining instructions below:
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.

DRAINING RECOVERY TANK

1. Remove drain hose from holder, position hose
over floor drain and twist off drain hose cap. To
completely drain recovery tank, hinge open tank
and flip up tank support stand to rest tank on
(Figure 25).
NOTE: If using a bucket to drain machine, do not use
same bucket for filling solution tank. This will prevent
possible solution line clogs.
2. Rinse out recovery tank after each use. This will
prevent foul odor buildup. Use a hose to rinse out
the recovery tank. Be careful not to spray water
into shut--off float screen.
14
FIG. 25
Home Find... Go To..

DRAINING SOLUTION TANK

1. Pull clear hose off hose barb at rear of machine
and drain solution into floor drain or bucket
(Figure 26).
FIG. 26
2. Rinse out solution tank with clean water after each
use and flush out solution flow system by pushing
solution flow lever forward. This will prevent
clogging due to chemical buildup. Use clear hose
to drain solution tank.
3. Reconnect clear hose to hose barb. Be certain
hose is completely pushed onto hose barb.

CHARGING BATTERIES

ATTENTION: To prolong the life of the batteries
and to provide optimum machine performance,
ONLY recharge the batteries after a total of 30
minutes of use or more. Do not leave batteries
discharged for lengthy periods.
The following charging instructions are intended for
battery chargers supplied with the machine. Only use
a battery charger with the following specifications to
prevent battery damage.

BATTERY CHARGER SPECIFICATIONS:

S
CHARGER TYPE: FOR LEAD ACID BATTERIES
S
OUTPUT VOLTAGE -- 24 VOLTS
S
OUTPUT CURRENT -- 25 AMPS
S
AUTOMATIC SHUT--OFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
1. Transport machine to a well ventilated area for
charging.