SNA 60 is conformed to norms following :
SNA 60
fully complies the decree 98-1143 issued 15 December 1998 regarding maximum audio levels
1°
FIXING
Fix SNA60 by openings X, Y, Z (see page 6), directly on wall.
Dimensions :
2°
AERATION
3°
MAINS SUPPLY
SNA60 is a equipment linked permantly in power supply; a power switch is not provided, in order to
not stop sound level monitoring.
Two pole power switch with a contact openning at least 3 mm, have to be installed in the circuit to
respect safety prescriptions.
Never dismantle the equipment, without having taken the precaution of removing the power.
4°
EARTHING
SNA60
NEVER
5°
BATTERY REMPLACEMENT
SNA60 mother card uses a Lithium battery to save the clock for several years.
The user is not entitled to change this battery.
ATTENTION:
AMIX
INSTALLATION AND SAFETY
EN60065, EN55013, EN55020, EN60555-2, et EN60555-3
According to the Directives 73/23/EEC, 89/336/EEC et 93/68/EEC
Install in a well ventilated place, and out of liquids streams.
For easier areation, fix SNA60 in vertical position wall.
Do not lock the vents.
Do not put things on the equipment.
Forsee a 50 mm free space over the equipment
Avoid high temperature exposure.
Never expose SNA60 to rain snow or moisture.
features a terminal to be wired to the building electrical earth
use the equipment without earthing, and check the earth quality before starting.
Risk of explosion if the battery is not properly fitted.
The battery replacement should be made by an approved fitter, and the battery
should be the same or exact equivalent.
Concerning environmental protection, do not throw the old battery, but leave it in
an appropriate place of collection.
220 mm
4
230 mm
.
.
SNA 60