2. INSPECTION AND STORAGE

At the time of receiving the equipment carefully cross check all the elements against the shipping documents in order
to ensure that all the crates and boxes have been received. Inspect all the units for any visible or hidden damage.
In the event of shipping damage, write precise details of the damage on the shipper's delivery note
and send immediately a registered letter to the shipper within 48 hours, clearly stating the damage
caused. Forward a copy of this letter to the manufacturer or his representative.
Never store or transport the unit upside down. It must be stored indoors, completely protected from rain, snow etc.
The unit must not be damaged by changes in the weather (high and low temperatures). Excessively high temperatures
(above 60 °C) can harm certain plastic materials and cause permanent damage. Moreover, the performance of
certain electrical or electronic components can be impaired.

3. WARRANTY

The appliances are delivered fully assembled, factory tested and ready to operate.
Any modification to the units without the manufacturer's prior approval, shall automatically render the warranty
null and void.
The following conditions must be respected in order to maintain the validity of the warranty:
²
Commissioning shall be performed by specialised technicians from technical services approved by
the manufacturer.
²
Maintenance shall be performed by technicians trained for this purpose.
²
Only Original Equipment spare parts shall be used.
²
All the operations listed in the present manual shall be performed within the required time limits.
OF NON-COMPLIANCE WITH ANY OF THE ABOVE CONDITIONS.

4. PRESENTATION

4.1. GENERAL

All the models in the SYSAQUAC condensing unit range are produced to state-of-the-art design and manufacturing
standards. In this way, they offer guarantees of high performance and reliability as well as the capability of adapting
to all types of air conditioning installations operating. SYSAQUAC is designed for outdoor mounted applications,
and is not suitable for any use other than those specified in the present manual.
Improper usage of the unit or a use for purposes other than those originally intended, without the prior approval
by the manufacturer or its agents, could result in the unit functioning outside its safe operating limits and could
present risks to both personnel and property.
SYSAQUAC units are dedicated to commercial or industrial air conditioning applications. They have to be connected
to a direct expansion exchanger. Piping connection lines, expansion valve and indoor units are not provided, and
their selection and installation are under customer responsibility.
After the units are assembled, the refrigerating and electrical circuits are tested at the factory in order to guarantee
correct operation.
The units are filled with a test refrigerant fluid charge to manage pressure tightness tests.
THE WARRANTY SHALL BE NULL AND VOID IN THE EVENT
5