Electrical Connection - Scheppach DP16SL Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
Positioning table and workpiece, Fig. 15
Always place a piece of back up material (A) ('wood,
plywooood) on the table undemeath the workpiece.
This wiII prevent splitering or making a heavy burr on
the underside of the workpieces as the drill bit breaks
through. To keep the back up material from spinning
out of control it must contact the left side of the col-
umn (B) as illustrated.
Warning:
To prevent the work piece or the backup material from
being torn from your hand while drilling, position them
to the left side of the column. If the work piece or the
backup material are not long enough to reach the col-
umn, clamp them to the table. Failure to do this could
result in personal injury.
Note: for small pieces that cannot be clamped to the
table, use a drill press vise (accessory).
The vice must be clamp or bolt to the table to avoid
injury from spinning work and vise or tool breakage.
Drilling a hole
Make a dent in the workpiece where you want the
hole, using a center punch or a sharp nail. Before
turning the switch on, bring the drill down to the
workpiece lining it up with the hole location. Turn the
switch on and pull down on the feed handles with onIy
enough effort to allow the drill to cut.
Feeding Too Slowly might cause the drill bit to burn.
Feeding Too Rapidly might stop the motor, cause the
bett or drill to slip, tear the workpiece loose, or break
the drill bit.
When drilling metal, it may be necessary to lubricate
the tip of the drill with motor oil to prevent burning the
drill bit.
Working with the laser (Fig. 16)
To turn on the laser pess switch (16)
Align the illustrated borehole in the focal point (F) of
the laser, place the drill and begin drilling.
Maintenance
Warning:
For your own safety, turn the switch off and remove
plug from power source outlet before any operation of
maintenance on our drill press.
Keep your appliance clean.
Be careful some household cleaning products and
solvents such as benzine, trichloroethene, chloride,
ammonium, etc., can damage plastic parts.
To avoid motor darnage, blow out or vacuurn fre-
quently this motor to keep drill press dust from inter-
fering with normal motor ventilation.
Power cord.
To avoid shock or fire hazard, if the power cord is
worm or cut, or damaged in any way, have it replace
immediately.
26
GB
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
Lubrication.
All of the ball bearings are packed with grease at the
factory. No further lubrication is required.
Periodically lubricate the splines -grooves -in the
spindle and the rack.
To lubricate the splines, bring do~ the quill and ject
the grease into the spindle from the top of the pulley.
Bring the quill up and down a few times. To lubricate
the rack, bring down the quill and apply grease to the
outer surface of the quill. Bring the quill up and down
a few times.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Carbon brushes, v-belt, drill, battery
* Not necessarily included in the scope of delivery!
m Electrical connection
The installed electric motor is completely wired ready
tor operation.
The terminal complies with the relevant VDE and DIN
regulations.
The customer's connection to the power supply sys-
tem, and any extension cables that may be used,
must conform with local regulations.
Defective electrical connection cables
Electrical connection cables often suffer insulation
darnage.
Possible causes are:
• Punch points when connection cables are run
through window or door gaps.
• Kinks resulting from incorrect attachment or laying
of the connection cable.
• Cuts resulting from running over the connecting
cable.
• Insulation darnage resulting from forcefully pulling
out of the wall socket.
• Cracks through aging of insulation.
Such defective electrical connection cables
must not be used as the insulation darnage
makes them extremely hazardous.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN".
The printing of the type designation on the connec-
tion cable is mandatory.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

4906807901

Table des Matières