Storage; Electrical Connection - Scheppach DP50 Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
• Remove swarf, dust and dirt with a vacuum clean-
er if necessary.
• Lubricate the moving parts regularly.
Maintenance
The device has no parts that require maintenance.
Replacing the chuck (fig. 10)
m Warning! Pull out the mains plug!
Tools required (not included in the scope of delivery):
1x open-ended spanner (flat)
1x Allen key
2.5 mm
• Loosen the Allen screw by turning it counter-clock-
wise ca. 2 turns.
• Hold the chuck shaft in place with the spanner
and unscrew the chuck counter-clockwise with
your free hand.
• Fasten the new chuck in reverse order.
When replacing the chuck, use only chucks ap-
proved by the manufacturer.
Order number: 390 6813 010
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: Carbon brushes, drill bit
* Not necessarily included in the scope of delivery!

13. Storage

Store the equipment and accessories out of children's
reach in a dark and dry place at above freezing tem-
perature. The ideal storage temperature is between
5 and 30 °C.
Store the electric tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.

14. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cable used must also comply with these
regulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Faulty power supply cables
Insulation damage often occurs at power supply ca-
bles.
Causes are:
• Pressure points when power supply cables are
routed through the window or door gaps
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
16 mm
• Bends due to improper fastening or guiding of the
power supply cables.
• Interfaces by running over the power supply ca-
bles.
• Insulation damage by pulling off the wall outlet.
• Cracks due to ageing of the insulation.
Such defective power supply cables must not be
used and are extremely dangerous to life because of
the insulation damage!
Check power supply cables regularly for damage.
Make sure that the power cable is not connected to
the mains supply when you check.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking H05VV-F.
The printing of the type designation on the connec-
tion cable is mandatory.
If it is necessary to replace the power cable this
should be done by the manufacturer or their repre-
sentative to avoid safety hazards.
AC motor:
The mains voltage must be 220 - 240 V ~ .
• Extension cables up to 25 m length must have a
cross section of 1.5 mm
.
2
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Motor data - type plate
GB
25

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5906817901

Table des Matières