Other Dangers
Insufficient Local Lighting
Unproper lighting represents high safety risk.
Care for sufficient lighting at work with the
apparatus.
Slip, Stumble or Fall of Persons
The cables and hoses may cause stumple and
fall. Keep order on the working place.
Disposal
The instructions about the disposal of wastes are shown in
the pictograms placed on the apparatus and/or on the
packing. For the explanation of individual marks see Chapter
„Marking on the Apparatus".
Requirements on the Operator
The Operator shall carefully read Operation Manual before
using the apparatus.
Qualification
No special qualification is needed for the work, just detailed
training provided by the specialist.
Minimum Age
The apparatus may operate only persons at the age of 16
years and more. An exception makes the case is a special
training for acquiring the skill under supervision of a lecturer.
Training
Only corresponding instruction is needed for the use of the
apparatus. No special training is necessary.
Technical data
Engine:
Engine Power:
Stroke Volume:
Idle speed:
Maximum Pressure:
Working Pressure:
Water Output:
Tank Volume:
Oil Volume:
Weight:
Storing
Should the engine be not used for longer period of time or
should it be stored for at least one month, following working
steps shall be observed.
Discharge all petrol from the tank and from the choke.
Remove spark plug.
Put about 1 tablespoonfull of clean engine oil into
the cylinder for spark plug insert.
At switched off engine pull several times carefully
the starting cord. Then insert the ignition plug again
and pull out the starting cord until the piston is
completely up (compression point OT). Stop pulling
as soon as you feel perceptible resistance.
Store the apparatus in a well ventilated, dry place under
protective cover so that no dust and dirty may be deposited
on it.
Measures for Storing for Winter or for a longer Period of
Time
If the apparatus is not used for at least 3 months or if frosts
are expected in winter months, the pump shall be properly
protected against damage caused by frost or against freezing.
Prepare proper solution for protection in winter months
according to the instruction on the protective means. Pour the
solution carefully into the inlet of the apparatus. After the
solution dripped away at the outlet, close it with cork or
another suitable plug or closing device. Place into the inlet so
much non-freezing liquid till the pump is full. Then close the
4-Stroke-OHV
4 kW (5,5 PS)/3600 min-1
163 cm³
1400 min-1
210 bar
160 bar
10l/min
3,6 l
0,6 l
32,5 kg
inlet with cork or another suitable plug. Before using the
apparatus after treatment with protective non-freezing liquid
all liquid shall be discharged from the pump, hose and water
piping leading to the jet. After first restarting the apparatus
again a bit of liquid may pour out from the pump. This pouring
will stop shortly.
Installation
Remove all packing material from the apparatus. Check the
apparatus, all parts and accessories and make sure that no
part is missing and that no damage occurred during the
transportation.
Setting on the Handle and Guides (Fig. 6)
Fix the handle and the device for placing accessories to the
frame of the apparatus. Stick the lock screws through the
holes outside the apparatus and fix them with securing collar.
Tighten manually. Fix the hook for high-pressure hose and
guides to the upper handle.
Wheel Installation (Fig. 3)
Before fixing the wheel loose the screw and release the axis.
Set the wheel on the axis and secure it with delivered locking
nut.
Pump Plug (Fig. 10)
Observe the rules of your water company. According
to the EN 61 770 standard, the appliance must not be
immediately connected to public drinking water supply.
However, short-term connection is according to DVGW
(German Association of Gas and Water Branch) accepted if
there is a backflow barrier with air intake inbuilt in the supply
line. Also mediated connection to public drinking water supply
through free output according to EN 61 770 is allowed; e.g. by
inserting a container with a float valve. Immediate connection
to the line network not designed for distribution of drinking
water is admissible.
The apparatus is furnished with the plug preventing leakage
of the oil during transportation. Remove the transport plug
and replace it with the plug with bleeding function that is
included in the delivery. The pump of the apparatus has
closed oil circulation that needs no maintenance. (Refuelling
or exchange of oil is not necessary).
Before Putting into Operation
Following operations shall be performed before putting the
apparatus into operation:
pour the engine oil into gearbox
pour the petrol into the tank
connect the high-pressure hose to the spray gun
and to the pump
connect the pump to the water main
connect the jet to the spray gun
Important Warning: The engine and the pump of your
apparatus needs some period of time to run in. Therefore
the apparatus will operate with full output after a few
hours of operation.
Pouring the Engine Oil into Gearbox (Fig. 12)
Never try to start the apparatus if there is not enough
corresponding oil in the engine. There is no oil in the
apparatus at delivery thereof. If the apparatus operates
without (sufficient quantity of) engine oil, the engine will get
damaged. Place the apparatus on flat surface and remove the
cover from the oil tank. Fill the engine oil at least up to the half
of the measuring bar length.
Pouring the Petrol into the Tank (Fig. 2)
High-pressure cleaner is driven by a 4-stroke engine requiring
leadless petrol. Use suitable funnel for filling up the petrol.
Make sure there is not too much petrol in the tank and
prevent spraying the petrol out. The oil should reach up to the
fuel filter, not higher.