Les langues disponibles

Important: Changes in the settings market with ( * ) for the Selectrix
mode of operation automatically lead to changes in the DCC mode of
operation and versa!
CV
Discription
1
address
3
acceleration delay
4
braking delay
5
* maximum speed
17
extendet address (upper part)
18
extendet address (lower part)
29
bit 0: Travel direction polarity reversal
bit 1: number of speed levels 14/28
bit 2: DCC Operation with braking Block
DCC-, Selectrix and DC power operation
bit 5: address size 7 bit / 14 bit
49
* pulse width for motor control
50
* ule variant
51
* bit 0: motor polarity reversal
bit 1: lighting polarity reversal
bit 2: track polarity reversal
*** The values for the desired settings must be added.
DCC Value
1 - 127
0 - 127
0 - 127
1 - 7
CV 29,
bit 5=1
CV 29,
bit 5=1
Value
0 / 1
***
0 / 2
0. 1, 2, 3, 4, 5,
0 / 4
6, 7, 32, 34,
35, 36, 37,
0 / 32
38, 39
0 - 3
0 - 3
0 / 1
***
0 - 7
0 / 2
0 / 4
Selectrix
Factory
Setting, DCC
Value
/ SX
3 / 1
1 - 99
5 / 5
1 - 7
5 / 5
1 - 7
3 / 3
1 - 7
255 / —
not necessary
255 / —
not necessary
not
6 / —
necessary
1 / 2
1 - 4
2 / 3
1 - 4
4 / —
not necessary