I. INSTALLATION INSTRUCTIONS
1. LOCATION
IMPORTANT
1. This icemaker is not intended for outdoor
use. Normal operating ambient temperature
should be within 5°C to 40°C. Water
connection is cold water only. Operation of
the icemaker, for extended periods, outside of
these normal temperature ranges may affect
production capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm clearance at rear and sides for
proper air circulation and ease of maintenance
and/or service should they be required. Allow
60 cm clearance on top to allow for removal
of the auger.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything on top of the icemaker
or in front of the louver.

2. ELECTRICAL CONNECTIONS

WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker.
Disconnect the main power supply before any
maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC,
12A supply. The electrical supply must be protected
by a suitable circuit breaker.
* Usually an electrical permit and services of a
licensed electrician are required.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow
must be connected to the terminal in the plug
which is marked with the letter E or by the symbol
or coloured Green or Green-and-Yellow. The
wire which is coloured Blue must be connected to
the terminal which is marked with the letter N or
coloured Black. The wire which is coloured Brown
must be connected to the terminal which is marked
with the letter L or coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded
on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used without
a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's
reference number stamped on the plug.
Supply of replacement fuse covers can be obtained
from Hoshizaki Parts/Service Centres.
Fuses should be rated at 12A and approved to
BS 1362.
3. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable cold water supply only.
3