3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm clearance at rear, sides and top
for proper air circulation and ease of
maintenance and/or service should they be
required.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything on top of the icemaker
or in front of the Louver.
7. This icemaker will not work at subfreezing
temperatures. To prevent damage to the water
supply line, drain the icemaker when air
temperature is below zero (see "II. 2.
PREPARING THE ICEMAKER FOR LONG
STORAGE" in the instruction manual).
8. The noise from this icemaker is 55 dB or less.
3. INSTALLATION
* Incorrect installation can cause harm to people,
animals or things, for which the manufacturer cannot
be held responsible.
1) Position the icemaker in the selected permanent
site.
2) Level the icemaker in both the left-to-right and front-
to-rear directions by adjusting the legs.

4. ELECTRICAL CONNECTIONS

WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker.
Remove the plug from the mains socket before
any maintenance, repairs or cleaning is
undertaken.
* This icemaker must have a separate power supply
or receptacle of 220 - 240V.
* The main control box circuit breaker is rated at 6A
and should only be replaced by a qualified service
engineer.
* Usually an electrical permit and services of a
licensed electrician are required.
* If the supply cord and the plug should need to be
replaced, it should only be done by a qualified
service engineer.
For the U.K. and the Republic of Ireland only
* The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colours of the wire in the mains lead of this
appliance may not correspond with the coloured
markings identifying the terminals in your plug,
proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal
which is marked with the letter N or coloured Black.
The wire which is coloured Brown must be connected
to the terminal which is marked with the letter L or
coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded on
plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the power
supply cord, it must be disposed of. There should
be no attempt to reuse it. Inserting such a plug into
a socket elsewhere presents a serious risk of
electrical shock.
* The non-rewirable plug must never be used without
a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer's reference
number stamped on the plug.
Supply of replacement fuse covers can be obtained
from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS
1362.