Accessories
Description
Plastic sacks, standard
Fine fi lter
Microfi lter
Warranty
Th e warranty period for this machine is two years and co-
vers manufacturers faults. Th e warranty is valid under the
condition that the machine is used under normal conditions
on the task for which it was designed and is maintained
properly. Normal wear is not covered by this warranty.
TROUBLE SHOUTING
Problem
Motor will not start.
The motor stops directly
after starting.
Pump runs but no suction.
Pump runs but poor suction. Hole in the hose.
Machine blows dust.
Abnormal sound from
machine.
2012-01-30
Part no
Other accessories — see Dustcontrol catalo-
gue.
4614
4292
4422
Service performed by other than Dustcontrol or its aut-
horized agent voids automatically the warranty. No other
warranty express or implied is applicable.
Fault
Machine not connected.
Thermal overload tripped.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose plugged.
No plastic sack on the
cyclone.
Pump rotation backwards.
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
Filter is perforated or has
come loose.
Particles in the pump.
DC 5800c 11 kW S - 11
Solution
Make sure connection.
Wait 5 minutes.
Change to
correct circuit.
Electrician should adjust.
Connect the hose.
Find and remove block.
Mount the correct sack.
Electrician should change
phases.
Change or repair hose.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Check the fi lters and change
if necessary.
Order service.
Part No 9091-B