Service

With cleaning and maintenance on the machine,
the power cable should be disconnected from the
supply. Check regularly that the electrical cable is
not damaged.
The fi ne fi lter should be changed at least once per
year. Use only original spare parts. If the machine
is used with a microfi lter/HEPA fi lter, this should be
changed every 300 running hours.Use breathing pro-
tection when changing the fi lter. Care must be taken
during the fi lter change not to expose unprotected
persons to harmful dust. Used fi lters should be sealed
in a plastic sack and disposed of properly.
The DC 5800c 5 kW should be performance tested

Accessories

Description
Plastic sacks, standard
Fine fi lter
Microfi lter
Warranty
The warranty period for this machine is two years
and covers manufacturers faults. The warranty is
valid under the condition that the machine is used
under normal conditions on the task for which it was
designed and is maintained properly. Normal wear is
not covered by this warranty.
Part no
4614
4292
4422
DC 5800c 5 kW - 10
at least once per year because it may be used with
hazardous materials. Worn parts must be replaced.
Never compromise the function of the DC 5800c
5 kW, use only original spare parts.
The turbopump has a very long maintenance free ser-
vice life. After approximately 10 000 running hours,
the radial seal between the motor and pump housing
should be greased. Bearings and seals in the motor
and turbopump should be checked and lubricated.
Parts worn beyond serviceable tolerances should be
replaced with genuine spare parts.
Other accessories — see Dustcontrol
catalogue.
Service performed by other than Dustcontrol or its
authorized agent voids automatically the warranty.
No other warranty express or implied is applicable.