Operation; Service; Accessories - Dustcontrol DC 5800c 5.5 Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Operation

Connect the machine to a suitable power source according
to the specifi cations found on the identi-fi cation label on
the machine. If an extension cord is to be used with the
unit, it should be suitably rated according to the prevailing
electrical code and be at least water resistant. Check rotation
of the motor at startup. On machines equipped with a phase
reverser, incorrect rotation can be easily changed. Machines
not equipped with a phase reverser will require the service
of a qualifi ed electrician to interchange two phases in the
power supply.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running or if the machine is equipped with a fi lter
monitor, when this is in the red area.
For fi lter cleaning:
1.
Start the machine.

Service

With cleaning and maintenance on the machine, the po-
wer cable should be disconnected from the supply. Check
regularly that the electrical cable is not damaged.
Th e fi ne fi lter should be changed at least once per year.
Use only original spare parts. If the machine is used with
a microfi lter/HEPA fi lter, this should be changed every
300 running hours.Use breathing protection when chang-
ing the fi lter. Care must be taken during the fi lter change
not to expose unprotected persons to harmful dust. Used
fi lters should be sealed in a plastic sack and disposed of
properly.

Accessories

Description
Plastic sacks, standard
Fine fi lter
Microfi lter
2011-07-11
Part no
4614
4292
4422
DC 5800c 5.5/7.5 kW - 10
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the fi ne
fi lter must be changed.
Th e plastic sack should be changed only after the fi lter has
been cleaned. Th e sack should be changed when the dust
level is about 5 cm under the foot valve. Th e plastic sack
should be sealed after removal from the machine.
Use only original plastic sacks.
Th e DC 5800c 5.5 kW should be performance tested at
least once per year because it may be used with hazardous
materials. Worn parts must be replaced.
Never compromise the function of the DC 5800c 5.5 kW,
use only original spare parts.
Th e turbopump has a very long maintenance free service
life. After approximately 10 000 running hours, the radial
seal between the motor and pump housing should be
greased. Bearings and seals in the motor and turbopump
should be checked and lubricated. Parts worn beyond
serviceable tolerances should be replaced with genuine
spare parts.
Other accessories — see Dustcontrol catalo-
gue.
Part No 9090-B

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dc 5800c 7.59090-b

Table des Matières