Operation
Connect the machine to a suitable power source according
to the specifi cations found on the identi-fi cation label on
the machine. If an extension cord is to be used with the
unit, it should be suitably rated according to the prevailing
electrical code and be at least water resistant. Check rotation
of the motor at startup. On machines equipped with a phase
reverser, incorrect rotation can be easily changed. Machines
not equipped with a phase reverser will require the service
of a qualifi ed electrician to interchange two phases in the
power supply.
Th e fi lter should be cleaned 1-2 times per day with conti-
nuous running or if the machine is equipped with a fi lter
monitor, when this is in the red area.
Service
With cleaning and maintenance on the machine, the power
cable should be disconnected from the supply. Check regu-
larly that the electrical cable is not damaged.
Th e fi ne fi lter should be changed at least once per year. Use
only original spare parts. If the machine is used with a micro-
fi lter/HEPA fi lter, this should be changed every 300 running
hours.Use breathing protection when changing the fi lter.
Care must be taken during the fi lter change not to expose
unpro-tected persons to harmful dust. Used fi lters should
be sealed in a plastic sack and disposed of properly.
Th e DC 5800c 5 kW should be performance tested at least
once per year because it may be used with hazardous mate-
rials. Worn parts must be replaced.
Accessories
Description
Fine fi lter
Microfi lter
2011-08-12
Part no
4292
4422
DC 5800i 5.5 kW - 10
For fi lter cleaning:
1.
Start the machine.
2.
Close the shutter valve on the machines inlet.
3.
With slow, even motion open the pulse top by lifting
the handle. Repeat three to six times.
4.
Open the shutter valve.
5.
If the fi lter condition meter reads green work can con-
tinue, if in the red, pulse clean again. If after several
repetitions, the fi lter condition still shows red the fi ne
fi lter must be changed.
Never compromise the function of the DC 5800c
5 kW, use only original spare parts.
The turbopump has a very long maintenance free ser-
vice life. After approximately 10 000 running hours,
the radial seal between the motor and pump housing
should be greased. Bearings and seals in the motor
and turbopump should be checked and lubricated.
Parts worn beyond serviceable tolerances should be
replaced with genuine spare parts.
Other accessories — see Dustcontrol catalo-
gue.