Condensate drain

Compressors (Fig. 14)
Draining the condensate from the pressure vessel is
recommended during regular operation. Switch off the
compressor at the mains. Reduce air pressure in the
device to max. 1 bar by releasing air via a connected
device. Install the hose from the basic package into the
drain valve. Place a vessel under the hose and open the
drain valve (1) and drain the condensate from the tank.
Compressors with condensation and filtration unit
(Fig.15)
During regular use, condensation is automatically drained
via the drain valve of the condensation unit filter. To check
that the automatic drain is working properly, open the
valve (2) of the drain vessel (1) by turning to the left.
Release a small amount of condensate from the vessel.
Close the valve (2) by turning to the right.
Both compressor types can be equipped with an automatic
condensate drain on the air tank to allow condensate to
drain without operator intervention (see the Accessories
chapter).
Compressors with air dryer (Fig.16)
Condensate
from
automatically drained into a collecting bottle. The bottle
must be drained regularly, see Chapter 19.1
THE FOLLOWING IS REQUIRED BEFORE ANY FOLLOW-UP CHECKS
Forcabinet-mounted compressors, unlock the lock on the top panel of the cabinet and lift.
19.6.

Safety valve check

(Fig. 17)
When the compressor is operated for the first time, make
sure that the safety valve is working properly. Turn the
screw (2) on the safety valve (1) several rotations to the left
until the safety valve releases air. Let the safety valve vent
for only a few seconds. Turn the screw (2) to the right until it
seats, closing the valve.
Never use the safety valve to vent air pressure in the air tank. It could damage
the safety valve. The valve is set to the maximum permitted pressure by the
manufacturer. Adjustments are not permitted!
10/2018
compressors
with
Fig. 14
air
dryers
is
- 31 -
1
1
Fig.15
2
Fig.16
:
1
2
Fig.17
NP-DK50 2x2V 110-2_10-2018-MD A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dk50 2x2v/110sDk50 2x2v/110mDk50 2x2v/110s/m

Table des Matières