Tab. 3
8 – 10 bar
Nominal voltage /
frequency (*)
Performance
at 8 bar
Working pressure (**)
Performance with KJF-2
at 8 bar
Max. current
Motor power
Air tank volume
Air quality – filtration
Maximum operating
pressure of safety valve
Noise level at 5 bar
Duty cycle
PDP drying performance at
7 bar
Time to fill air tank from 0 to
9 bar
Dimensions (net)
w x d x h
Net weight (****)
Classification under
EN 60601-1
Notes:
(*)
When ordering, state the version of the compressor
(**)
For otherrange of pressure consult with supplier
(***) Weight of compressors with a KJF-2 unit _add 4 kg
(****) Information about the weight is for informative purposes only and applies to the product without any
additional accessories.
NP-DK50 2x2V 110-2_10-2018-MD A
DK50
2x2V/110
230/50
230/60
V / Hz
3x400/50
115/60
-1
Lit.min
210
bar
8.0 – 10.0
-1
Lit.min
210
16.5
A
6.2
2x1.2
2x1.2
kW
2x1.2
2x1.1
Lit.
110
m
-
bar
12.0
LpfA
73,0
[dB]
100%
-
s
256
mm
1085x490x815
110 (***)
kg
108 (***)
- 8 -
DK50
DK50
2x2V/110S
2x2V/110/M
230/50
230/60
230/50
3x400/50
115/60
3x400/50
210
8.0 – 10.0
8.0 – 10.0
210
16.9
16.6
6.6
6.3
2x1.2
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
110
-
12.0
55
73
100%
100%
+3°C
-
256
1200x725x992
1085x625x815
181 (***)
179 (***)
Class I.
DK50 2x2V/110
DK50
2x2V/110S/M
230/60
230/50
230/60
115/60
3x400/50
115/60
165
165
8.0 – 10.0
-
-
17.0
6.7
2x1.2
2x1.2
2x1.2
2x1.1
2x1.2
2x1.1
110
110
0.3
0.3
12.0
12.0
56
100%
+3°C
1200x725x992
117
188
115
186
10/2018