Dimensional Drawings; Ordering Information; Scope Of Delivery - SICK SFS60S-HRZT0S01 Notice D'instruction

Systèmes fiables de feedback moteur
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Connection type
Operating current
Output frequency for sine/cosine signals
Weight
Operating torque at 20 °C
Rotor moment of inertia
Max. permitted angular acceleration
Max. operating speed
7
Start up torque at 20 °C
Service life of ball bearings
8
Radial shaft movement, static
Radial shaft movement, dynamic
Shaft movement, axial, static
Shaft movement, axial, dynamic
Ambient data
Operating temperature
Storage temperature range (without packaging)
Relative humidity/condensation
Resistance to shocks
Resistance to vibrations
(in accordance with EN 60068-2-6)
EMC
Enclosure rating
Safety-related parameters
Safety integrity level
11
Performance Level
11
Category
Probability of a dangerous failure per hour (PFH
Mission time (T
)
8
M
Test rate
Max. request time
Safety-related accuracy
12
Safety-related measuring increment
Self-heating approx. 3.0 K per 1,000 rpm, note working temperature range in design.
7
The mission time can also be limited by the bearing service life specific to the application.
8
9
The EMC according to the standards quoted is achieved when the motor feedback system is
mounted in an electrically conductive housing, which is connected to the central earthing
point of the motor controller via a cable screen. The GND-(0 V) connection of the supply
voltage is also grounded here. If other shielding concepts are used, users must perform
their own tests.
The enclosure rating (in accordance with IEC 60529) is achieved with attached mating
10
connector and was tested with the shaft in a horizontal position.
For more detailed information on the exact configuration of your machine/unit, please
11
consult your relevant SICK branch office.
12
The values displayed apply to a diagnostic degree of coverage of 90%, which must be
achieved by the external drive system.In the event of resonance, suitable tests have to be
carried out on the entire drive system.
8024039/1EH9/2021-12-17/de, en, es, fr, it
SFS60S-HRZT0S01
Cable, 8-wire, 0.6 m with M23
connector
≤ 80 mA
0 kHz ... 200 kHz
≤ 0.25 kg
0.6 Ncm
56 gcm²
≤ 500,000 rad/s²
6,000 rpm
0.8 Ncm
3.6 × 10
9
Rotations
± 0.3 mm
± 0.05 mm
± 0.5 mm
± 0.1 mm
–30 °C ... +85 °C
–40 °C ... +90 °C
90%, condensation not permitted.
100 g / 6 ms (in accordance with EN
60068-2-27)
20 g / 10 ... 2,000 Hz
EN 61000-6-2, EN 61000-6-3
IP 65
10
SIL2 (IEC 61508), SILCL2 (EN 62061)
PL d (EN ISO 13849)
3 (EN ISO 13849)
)
12
1.7 x 10
-8
D
20 years (EN ISO 13849)
Not required
Continuous (analog signals)
± 0.09° (for square counting)
0.09° (for square counting)

9.1 Dimensional drawings

Figure 1: Dimensional drawing of through hollow shaft with cable outlet, M23
male connector (all dimensions in mm)
Operating temperature measuring point (freely selectable, around the
1
housing surface area in each case, approx. 3 mm away from flange)
Vibration measuring point (on the housing front face in each case,
2
approx. 3 mm away from edge of housing)
Keyway
3

10 Ordering information

Type
SFS60S-HRZT0S01
Table 4: Ordering information
9
11 Appendix

11.1 Scope of delivery

Safe motor feedback system
Feather key with M4 screw
General safety notes
Operating instructions
You can find additional accessories in the product information at
12 Conformities and certificates
You can obtain declarations of conformity, certificates, and the current operating
instructions for the product at www.sick.com. To do so, enter the product part
number in the search field (part number: see the entry in the "P/N" or "Ident. no."
field on the type label).
The SFS60S/SFM60S safe motor feedback system family was manufactured in
accordance with the following directives:
the machinery directive 2006/42/EC
the EMC directive 2014/30/EU
Part number
1098876
SFS60S/SFM60S | SICK
www.sick.com
7

Publicité

Table des Matières
loading

Table des Matières