Autodiagnostic Leds - golmar V2PLUS Manuel D'installation

Portier vidéo avec installation de 2 fils sans polarizer
Masquer les pouces Voir aussi pour V2PLUS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

92
D
escription of the configuration dip-switch of the
EL500/V2PLUS microprocessor module
The SW1 configuration dip switch is located at the right side of
the circuit. It is accessed by opening the terminal connection
block protection cover .
Factory default
Green
Red
If the short circuit is removed before 2
*
minutes (approx.), the door panel will
automatically reset. Past this time it
will be necessary to switch it off and
then switch it on again the power.
DOOR PANEL INSTALLATION
.
Set the master door panel to OFF, if there is a MC-V2Plus multiplexer with
access doors panels in the installation or backbone, only one door panel
can be configured as the master, the rest must be slaves and set to ON.
Each backbone must only have one door panel or CD-V2Plus
converter configured as the master.
Set to ON the switch number 2 for monitor or telephones programming
Once the programming has finished, return the switch to the OFF position.
The programming process is described on pages 99 (monitors) and 102
(telephones)
.
Placed in ON allows autoswitch-on (audio and video communication without
having been called), if there is a MC-V2Plus multiplexer with access doors
panels in the installation or backbone activate this function only in one of
them; in systems with general door panel (necessary the use of converter CD-
V2Plus) this function can be activated in one door panel of each backbone.
Selects whether the door panel has a telecamera or not
door panel does not have a telecamera.
Set to ON so that the volume tone emitted by the door panel are HIGH, or
set to OFF if a LOW volume tone is desired.
Set to ON if there are distributors in the backbone (single-user or multi-user)
or the door panel is connected to the riser multiplexer MC-V2Plus with
daisy chain multiplexers.
Set to OFF if the backbone is daisy chain (without distributors) or the door
panel is connected to the riser multiplexer MC-V2Plus without daisy chain
multiplexers.
T
he autodiagnostic LEDs are found on the right side of the
circuit, beside the CN6 connector
Green LED
Fixed:
Blinking:
Red LED
Fixed: More than one module is configured as the Master
Blinking:
D
escription of autodiagnostic LEDs
.
Correct operation
.
Door panel is being programmed (dip-switch 2
is ON
).
or module is faulty.
There is a short circuit in the installation between
the bus wires.
.
. Set to ON