For Your Safety; Operation; Switching The Interior Sauna Light On / Off; After Lengthy Non-Use - Sentiotec K1-NEXT Instructions De Montage / Mode D'emploi / Garantie

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
1

For your safety

CAUTION - Damage on the device:
Do no pour water over the sauna control nor use too much water when cleaning it.
To clean it, use a slightly damp cloth with mild soapsuds (rinsing agent).
2
Operation Diagram 4
WARNING - Fire hazard:
Before starting the sauna control make sure that there are no flammable objects on the oven.
1. Switch the sauna control on the ON / OFF switch 4. A self-test then follows.
2. Set the desired sauna temperature using the knob 2.
Mark the temperature that you feel agreeable, for example, with a pencil mark.
The control light 1 lights permanently.
If the measured cabin temperature is lower than the set desired temperature, the oven will start.
If the measured cabin temperature is higher than the set desired temperature, the oven will not start.
3. Switch off the ON / OFF switch 4 after a sauna bath.
The control light 1 extinguishes.
The sauna control is off.
3

Switching the interior sauna light on / off

1. Button 3 switches the interior sauna light ON / OFF.
4

After lengthy non-use

Disconnect the main fuses of the sauna control in the fuse box.
5

Errors and possible corrective measures

5.1 Automatic time restriction
The sauna control automatically switches the oven after 6 hours of permanent heating time off.
For further operation, switch off the ON / OFF switch 4 and switch it on again after 10 seconds.
5.2 Interior light does not light up
Switch off ON / OFF switch 4.
Disconnect main fuses of the sauna control in the fuse box.
Change the filament lamp.
Connect the main fuse and press button 3.
If the interior light still does not light up, notify your customer service.
5.3 Red pilot lamp 1 flashing
The sauna control automatically switches the heat off if the temperature exceeds about 139°Celsius.
The sauna control is no longer operational:
1. Disconnect the main fuses of the sauna control in the fuse box.
2. Contact your customer service.
3. Mark the device as defective.
WE DO IT FIRST.
Instructions for use for the user
P. 7/10
EN