12
8 Technical data
Input data
Type
Measuring range
Direction of rotation
Max. axial load
Max. radial load
Housing material
Shaft material
Output data
E
Output signal, permitted load
resistance
Resolution
Accuracy
(at room temperature)
Accuracy
(over the temperature range)
Repeatability
Characteristic curve
Ambient conditions
Operating temperature range
Storage temperature range
mark
- Marked
Vibration resistance to
DIN EN 60068-2-6:2008
Shock resistance to
DIN EN 60068-2-27:2010
Protection class to DIN EN 60529
Safety-related data
Performance level
Based on
PL
Architecture
Safety Integrity Level
Based on
SIL
Architecture
Other data
Supply voltage
Residual ripple of supply voltage
Power consumption
Weight
Note: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are provided
1)
with mounted female connector having the corresponding protection class
Edition: 2021-02-18
Absolute singleturn
0 .. 360 °
No restrictions
60 N
100 N
Stainless steel
Stainless steel
4 .. 20 mA
load ≤ 500 Ω
12 Bit
± 0.15° typ.
± 0.3° max.
± 0.075° / 10 K typ.
± 0.15° / 10 K max.
≤ ± 0.05 °
Linear, cw / ccw (factory-set)
- 40 .. + 85 °C
- 40 .. + 85 °C
EN 61000-6-1 / 2 / 3 / 4
E13*10R00*10R05*14136*00
7.5 mm (5 Hz ≤ f < 8.2 Hz)
2 g (8.2 Hz ≤ f < 2000 Hz)
20 g (11 ms in 3 axes)
IP 67, IP 6K9K (electronics)
1)
DIN EN ISO 13849-1:2008
d
Category 2
DIN EN 61508:2010
2
1oo1 /1oo2
9 .. 36 V DC
≤ 5%
< 1.4 W
~ 120 g
HYDAC ELECTRONIC GMBH
HAT 1200 Analogue Safety
Part No.: 669956