Technical Data - HYDAC ELECTRONIC HNT 122 000 Serie Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14

7 Technical Data

Input data
Measuring ranges
1)
Probe length
Max. speed of change in the fluid level
Mechanical connection
Torque value, recommended
Parts in contact with medium
E
Measuring medium
Output data
Analogue output, permitted load resistance
3)
Accuracy
Temperature coefficient
Non linearity
Repeatability
Ambient conditions
Ambient temperature range
Storage temperature range
Fluid temperature range
Max. tank pressure
- mark
Vibration resistance according to
DIN EN 60068-2-6
Shock resistance to
DIN EN 60068-2-27 (11 ms)
Protection class to DIN EN 60529
Other data
Supply voltage (U
Residual ripple of supply voltage
Current consumption (without output)
Weight
Note: Reverse polarity protection of the supply voltage, excess voltage and short circuit protection
are provided.
FS (Full Scale) = relative to the full measuring range
1)
Other probe lengths on request
2)
Other measuring media on request
3)
Specified for calm, non-turbulent fluid
4)
-25°C with FPM seal, -40°C on request
5)
With mounted coupling box with appropriate protection
Edition: 2017-05-31
All manuals and user guides at all-guides.com
2)
4)
5)
)
B
HYDAC ELECTRONIC GMBH
178│208│298│338│448│658 mm
250│280│370│410│520│730 mm
No restrictions
G ¾ A ISO 1179-2
30 Nm
Probe: Stainless steel (1.4301 / 1.4571)
3
Float : PP; 0.6 kg/dm
Seal: seal ring DIN 3869-27-FPM
Hydraulic oils, cooling lubricants
4 .. 20 mA, load : ≤ 500 Ω
0 .. 10 V, load : ≥ 1kΩ
≤ ± 1 % FS
≤ ± 0,01 % FS / °C
≤ ± 1 % FS
≤ ± 1 % FS
-25 .. +85 °C
-40 .. +100 °C
-40 .. +120 °C / -25 .. +120 °C
3 bar ( short-term 10 bar, t < 1 min)
EN 61000-6-1 / 2 / 3 / 4
7,5 mm (5 .. 8,2 Hz)
2,0 g (8,2 .. 150 Hz)
20 g
IP 67
9 .. 36 V DC
≤ 250 mV
PP
≤ 100 mA
Depends on length::
425 g (250 mm); 570 g (730 mm)
HNT 122x-x-xxxx-000
Part No.: 669940