HAT 1200 Analogue Safety
9 Packing / Transportation
Notes on packaging
Only use the original packaging!
The wrong packaging material can cause damage to the device during
transportation.
Notes on transportation
Do not drop the device or expose it to strong strokes!
Only use the original packaging!
The wrong packaging material can cause damage to the device during
transportation.
10 Order details
Resolution
2
= 12 Bit
Housing diameter
36
= 36 mm
Output signal
C01 =
Analogue 4 .. 20 mA, 3 conductor
Measuring range in ° and rotational direction
360R = 360°, clockwise rotation
360L = 360 °, anti-clockwise
Electrical connection
P01 = Installation plug M12x1; 5 pole, axial
Mechanical connection
V106 = Solid shaft, length 10 mm, diameter 6 mm
D106 = D-shape, length 10 mm, diameter 6 mm
Fixing type
M01 = Synchro flange with 4 threaded bores
Functional safety
S2PD
= SIL 2 acc. to IEC 61508 and PLd – Cat 2 acc. to DIN EN 13849-1
Modification
000 = Standard
1)
Note:
Other models on request
11 Scope of delivery
HAT 1236
operating manual
Edition: 2021-02-18
HAT 1 2 3 6 – XXX – XXXX – P01 – XXXX – M01 - S2PD – 000
1)
HYDAC ELECTRONIC GMBH
13
E
Part No.: 669956