HAT 1200 Analogue Safety
7 Interface description
7.1 Signal output: Analogue 4 .. 20 mA
mA
20
4
Measurement range
3
0°
Analog signal at limited measuring range
If the measuring range is just slightly exceeded or fallen below, the output signal will
continue at a linear rate. If the deviations in either directions are more significant, the
sensor switches to the "out of range" state (3mA) or to the greater/smaller position value
corresponding to the angle.
7.2 Timing start behaviour analogue signal
During the starting phase the output of the 3 mA is carried out for a period of about 1 sec.
(self diagnosis), afterwards, the signal output is 4-20 mA depending on the pre-set angle.
mA
20
Diagnostics
4
3
1 sec
Edition: 2021-02-18
180°
Analog signal at 360° measuring range
Signal output
HYDAC ELECTRONIC GMBH
mA
20
4
Measurement range
0
11
360°
Part No.: 669956
E