14
7 Technical data
Input data
Measuring ranges
1)
Rod length
Max. speed of change in the fluid level
Mechanical Connection
Tightening torque, recommended
Parts in contact with fluid
E
2)
Fluids
Temperature
Measuring range
Output data
Output signal
4)
Accuracy
Temperature coefficient
Non-linearity
Repeatability
Reaction time to DIN EN 60751
(Temperature probe)
Ambient conditions
Ambient temperature range:
Storage temperature range
Fluid temperature range
Max. tank pressure
- Marked
Vibration resistance
to DIN EN 60068-2-6
Shock resistance to
DIN EN 60068-2-27 (11 ms)
Protection class to DIN EN 60529
Protocol data for CANopen:
Communication profile
Device profile
Layer setting services and protocol
Baud rates
Transmission services
- PDO
- Transfer
Node ID/Baud rate
Other data
Supply voltage (UB)
Residual ripple supply voltage
Current consumption (without output)
Weight
Note: Reverse polarity protection of the supply voltage, excess voltage and short circuit protection are provided.
FS (Full Scale) = relative to the full measuring range
1)
Other rod lengths on request
3)
Note the permitted ambient temperature range
5)
-25°C with FPM seal, -40°C on request
6)
with mounted female connector having the corresponding protection class
Status: 2017/06/02
3)
5)
6)
HYDAC ELECTRONIC GMBH
mm │178│208│298│338│448│658
mm │250│280│370│410│520│730
Optional
3/4
G
A ISO 1179-2
30 Nm
Rod: Stainless steel 1.4301 / 1.4571)
Float: PP (Polypropylene); 0.6 kg/dm³
Seal: Seal ring DIN 3869-27-FPM
Hydraulic oils, cooling lubricants
-25 ... +100 °C
CANopen
Level: ≤ ± 1 % FS
Temperature: ± 1.5 °C
≤ ± 0.003 % FS / °C
≤ ± 1% FS
Level: ≤ ± 1 % FS
Temperature: ≤ ± 0.5 °C
t
≈ 100 s
90
-40 .. +85 °C
-40 .. +100 °C
-40 .. +120 °C / -25 to +120 °C
3 bar (short-term 10 bar, t < 1 min)
EN 61000-6-1 / 2 / 3 / 4
7.5 mm (5 .. 8.2 Hz) / 2.0 g (8.2 .. 150 Hz)
20 g
IP 67
CiA DS 301 V4.2
CiA DS 404 V1.3
CiA DSP 305 V2.2
10 kbit .. 1 Mbit corresp. to DS305 V2.2
Measured value as 16/32 bit and float, status
Synchronous, asynchronous, cyclical, measured value change
adjustable via LSS
9 .. 36 V DC
≤ 250 mV
SS
≤ 100 mA
Depending on length: 425 g (250 mm); 570 g (730 mm)
2)
Further fluids on request
4)
Specified for calm, non-turbulent fluid
HNT 112x-F11-xxxx-000
Mat. No.: 669923