16. Electrical: Have a certified electrician
run appropriate power supply to
motor, Fig. 23, Fig. 24, and Fig. 24b.
Size wire for 20 amp circuit. See
Motor Operating Data Table.
CAUTION
Never operate the motor on
line voltage less than 208V. Motor damage
may occur.
IMPORTANT
Use separate circuit for
each power unit. Protect each circuit
with time delay fuse or circuit breaker. For
single phase 208-230V, use 20 amp fuse.
Three phase 208-240V, use 15 amp fuse.
For three phase 400V and above, use 10
amp fuse. For wiring see Fig. 23, Fig. 24,
and Fig. 24b. All wiring must comply with
NEC and all electrical codes.
Note: 60Hz. single phase motor CAN NOT
be run on 50Hz. line without a physical
change in the motor.
Attach black wire
to one motor wire.
White
Black
Green
208-230V 60Hz
Single Phase
Attach ground wire here.
Attach ground wire to
screws provided.
Fig. 23
Cable Ties
Air Line
Hydraulic
Hose
Attach white
wire to one
motor wire.
Note: 60Hz. Single phase motor CAN NOT be run on 50Hz. line
without a physical change in the motor.
230V 60Hz
Single Ph
17. Oil Filling: Use Dexron III ATF, or hydraulic fluid that
meets ISO 32 specifications. System capacity is
fourteen (14) quarts. Use Dexron III ATF or equal. Fully
lower lift. Remove fill/breather cap, Fig. 22. Fill to
minimum fill line on tank, replace cap.
Note: If fill/breather cap is lost or broken, order
replacement.
12
Fig. 22
Single Phase Power Unit
MOTOR OPERATING DATA TABLE - SINGLE PHASE
LINE VOLTAGE
RUNNING MOTOR VOLTAGE RANGE
208-230V 50Hz.
208-230V 60Hz.
Black
Black
Green
White
White
Column
Fill/Breather Cap
Power Unit
197-253V
197-253V
Up
Switch
Black
M

Publicité