3
Technical data
Technical data of the pumps
Information /
GTF 600
pump type
Weight
Power P1 / P2
650W / 400 W
Speed
2750 rpm
Operating voltage
230 V; 50 Hz
Nominal cur-
rent (per pump)
Max. pump-
12 m³/h
ing capacity
Max. pump-
ing height
Max. temperature
Pumped medium
Protection rating
IP68 (3m)
Protection class
Operating mode
Motor protection
integrated
Recom-
mended fuse
C16 A
(Mono)
C16 A
Recommended
fuse (Duo)
Residual current
30 mA
device (RCD)
Tank
Data
Duo weight
Inlet
Pressure pipe connection
Ventilation
Pumping volume
Aqualift 100 tronic,
Aqualift 200 tronic
016-228_01
GTF 1250
6 kg
10 kg
1.3 kW / 0.8 kW
2700 rpm
230 V; 50 Hz
2.9 A
5.4 A
20 m³/h
8 m
10 m
35°C
35°C
IP68 (3m)
I
I
S1
S3 (50%)
integrated
C16 A
C16 A
30 mA
Values
30-40 kg depend-
ing on the pump type
DN 100/150
DN 40/50
DN 50/70
50l
100l
Fig. 1: Pumping capacity diagram
29 / 140