4.6
Mount the accessory parts
Manual diaphragm pump
If required, mount the manual diaphragm pump (art. no. 28680) on one of the connection points on both sides. If neces-
sary, this can be used to pump out the tank contents manually. To this end, cut the required front connection socket to the
required length and mount the manual diaphragm pump.
Alarm float switch
On request, an additional float switch for alarm level (art. no. 28016) can be mounted and connected to the control unit. The
configuration of the control unit must then be adjusted (
4.7
Route the mains cables out of the tank
Undo the screws, lift out the components.
Align the rotary discs to match each other (pay attention
to correct order, see coding).
Insert the mains cable(s) into the openings in the sides
and route up to the control unit or the power supply.
Re-install the cable gland and its components in the
reverse order.
4.8
Test for leaktightness/function
Fill the system with clean water.
Check that the tank and all connections are leaktight.
Insert the plug/Connect to the mains connection.
Re-insert the service access cover.