Warranty Claim Handling; Warranty Terms And Conditions; Technical Information - ENBIO S Mode D'emploi

Masquer les pouces Voir aussi pour S:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 62

10. WARRANTY CLAIM HANDLING

In order to report a problem with the device, fill out the Warranty Claim
Form available on the manufacturer's website www.enbio-group.com Our
Technical Service will contact you as soon as possible. If the device has
been damaged during transport, file your warranty claim with the delivery
note and photographic evidence of the damage found. In order to contact
us, visit our website, you will find all the information under the link:
www.enbio-group.com
ATTENTION! The warranty claim process will begin once our Tech-
nical Service receives a properly completed Warranty Claim Form.
If you send the device to the Technical Service, clean the chamber and tray,
perform decontamination and correctly secure the device for transport.
Preferably send the device in the original packaging. If you lack an appro-
priate packaging, please contact the Technical Service or your supplier.
If the device needs to be transported:
• Disconnect the demineralised water and condensate tubing.
• Wait until the process chamber cools down.
• Use the original or other appropriate packaging with protection lining.
The sender bears complete liability for damage during transport to the
Technical Service.

11. WARRANTY TERMS AND CONDITIONS

ENBIO sterilisers are covered by a standard 24-month warranty. Detailed
warranty terms and conditions are available from the supplier of this device.

12. TECHNICAL INFORMATION

Technical data
Power supply
Installed power
Operated Power
Maximum electric current
consumption
Operating pressure
Maximum pressure
Maximum process temper-
ature
Process chamber capacity
Mass
Process chamber dimensions
(LxWxH)
External device dimensions
(LxWxH)
Protection rating
Noise level
Process data archiving
Surrounding conditions:
Operating temperature range
Relative humidity
Storage temperature range
Relative humidity
Surrounding pressure range
ENBIO S
ENBIO PRO
230 V/50Hz
230 V/50Hz
3,25 kW max
3,25 kW max
1,60 kW
1,60 kW
15 A
15 A
2,1 Bar
2,1 Bar
2,3 Bar max
2,3 Bar max
137°C
138°C
2,7 l
5,3 l
15 kg
20 kg
292 x 192 x 45mm
300 x 200 x
90 mm
561 x 252 x
561 x 270 x
162mm
202 mm
IP20
IP20
40dB
40dB
USB drive
USB drive
from +5°C to +40°C
0-90%
from -20°C to +60°C
0-90%
900-1100 hPa
58

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pro

Table des Matières