SELECT A DIFFERENT LANGUAGE
1. Turn on Unit (press ON/OFF button)
2. Use UP/DOWN buttons to scroll to "SETTINGS" then press ENTER
3. Use UP/OWN buttons to scroll to "Language" (Figure 9) then press ENTER
4. Use UP/DOWN buttons to scroll to desired language and press enter to
select and save this language (or Press Back Arrow to abort and not select
a new language)
5. Press Back Arrow to return to the active grain display where you are ready
to test
NOTE: For English only versions, English will be the only displayed language.
Language
ADJUST GRAIN OFFSET
Let's start with an overview of grain offset. An offset is the way you adjust your
tester to your local grain elevator's table top tester. Some people call it a calibra-
tion, some call it an offset, and others call it a bias but all three terms mean the
same thing. Let's say your tester measures a sample of corn at 15% moisture but
your local grain elevator tester measures it at 14.5%. What you can do is pro-
gram a 0.5% moisture (enter a -0.5%) offset to your tester so it matches the grain
elevator.
NOTE: It's not uncommon to take your load of grain to two different grain
elevators and get a different result from each of their grain elevator testers.
NOTE: An offset adjustment can NOT be made to produce moisture readings
that are below or above the moisture limit for the selected grain.
IMPORTANT: Always obtain three test results from the grain elevator for the
sample being compared. The unit will average these three results. Compare this
average with the average of three tests by your moisture tester before making an
offset adjustments.
Operation
Figure 9. Language Selection