Operation; Testing And Replacing The Battery; Changing The Language; Checking The Test Cell Temperature - AgraTronix GMT-Grind Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TESTING AND REPLACING THE BATTERY

Turn the GMT-Grind Grain Moisture Tester on by
pressing and releasing the ON/OFF button.
Press the arrow keys until the text BATTERY
VOLTAGE is displayed. The actual battery volt-
age will be displayed in the lower left corner.
The battery voltage will now be displayed in the
lower left corner of the display.
The battery voltage should be higher than 7.2V. If
the battery is low, the GMT-Grind Grain Moisture
Tester automatically turns off.
The battery box is located on the end of the tester (see Figure 1). To replace
the battery, slide the battery door towards the top of the tester, then pull the
battery compartment out. Replace the battery.
Remove the battery from the tester if the tester is not going to be used for a
long period of time. To ensure the correct functioning of the tester, replace
the battery when needed. If a fault in the tester is suspected, always test the
battery first.
NOTE: A battery can slowly discharge itself even if the tester is not used.

CHANGING THE LANGUAGE

• Press the arrow keys until the text LANGUAGE is displayed.
• Now press TEST and use either of the arrow keys to select the lan-
guage you desire.
• Once the language you want is displayed, press TEST to exit.

CHECKING THE TEST CELL TEMPERATURE

• Press the arrow keys until the text TEMPERATURE is displayed.

Operation