AVERAGE MOISTURE MEASUREMENT FUNCTIONS
There are two "average" functions in your tester.
FUNCTION 1 is AVG num – This means the "number" of Averages (AVG). That
is, you can program your tester to automatically average up to 3, 6, or 9 consecu-
tive moisture measurements and display the result. The majority of users will not
adjust the default averaging mode of averaging every 3 consecutive moisture
measurements. We added averaging 6 or 9 readings for users who are using the
tester in unique applications.
FUNCTION 2 is Clear AVG – "Clear average" will clear the current average
moisture results. Let's say you just took moisture measurements in one grain bin,
but you are now done with that grain bin. Next you go to another grain bin to test
another batch of grain. You can clear the previous average and start fresh with the
averages for your next grain bin.
Now Let's discuss how to use and select each of the two AVG (Average) moisture
measurement functions.
FUNCTION 1 – AVG num (number of consecutive moisture measurements
to average)(see Figure 4.)
1. Turn on Unit (press ON/OFF button)
2. Use Up/Down buttons to scroll to "SETTINGS" then press ENTER
3. Use UP/DOWN Buttons to scroll to "AVG num"
4. Press ENTER until your desired number to average is displayed (3, 6 or 9)
5. Press back arrow to return to the grain to be tested.
AVG num
Example: You can take 3 consecutive moisture tests from the same batch of grain.
If test 1 is 15.5, test 2 is 15.3, and test 3 is 15.7, then the average moisture dis-
played will be 15.5 % moisture (average of the 3 consecutive tests). The current
moisture is also always displayed for each test.
Operation
Figure 4. AVG num Display in Menu
8
Number to
Average