Specifications And Measurement Tolerances - VOLTCRAFT VC5070 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifications and measurement tolerances

Specifications
Over-voltage category
Max. measuring voltage
Analogue display
Input resistance V range
Power supply
Operating temperature
Storage temperature
Operating altitude
Relative humidity
Temp. for guaranteed accuracy
Weight
Dimensions (LxWxH)
Measurement tolerances
Accuracy information in ± (% of the scale value). The accuracy is valid for one year at a temperature of
+23°C ± 5°C, and at a relative humidity of less than 75 %, non-condensing.
Constant voltage range, overload protection 500 V (range 0.05 V, max. 250 V)
Range
0.05 V
2.5 V / 10 V / 50 V / 250 V / 500 V
AC voltage range (40Hz - 400Hz), overload protection 500 V
Range
10 V / 50 V / 250 V / 500 V
Direct current range
Range
25 µA / 2.5 mA / 25 mA / 250 mA
10 A
38
CAT III 500V to ground potential
9V (PP3) + 2x AA
< 75%, non-condensing
160 x 104 x 44 (mm)
Accuracy
± 4%
± 3%
Accuracy
± 4%
Accuracy
± 3%
± 4%
500 V
with mirror scale
approx. 10MΩ
0°C to +40°C
-10°C to +50°C
max. 2,000 m
+18°C to +28°C
approx. 360 g
Note
Internal resistance 10MΩ
Note
Internal resistance 10MΩ
Note
± 3%
Voltage drop ≤ 250mV
F 0.5A /500V
not secured
max. 10 s with 15 min pause

Publicité

Table des Matières

Dépannage

loading

Table des Matières