Attention!
If the eccentric worm-drive pump is operated against a closed outlet,
an appropriate by-pass (pressure relief) valve must be used to limit
the maximum pressure.
Attention!
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
44/116
Original Operating Instructions High Viscosity Liquid Pump F 550 and Sanitary Pump F 560
The maximum operating pressure and the operating temperature
must not be exceeded.
High operating pressure may result in the containers or the hoses
bursting or becoming loose. Make sure that excessive pressure
does not result when filling a container.
Keep the air escaping and the displacement in mind when immers-
ing the pump in the liquid. Lower the pump carefully.
Fill carefully and at an appropriate speed to avoid leakage of the
liquid.
After the filling, allow the excess to drip off the hand nozzle.
There may be liquid left in the outlet tube, which will then leak out.
Install appropriate splash guards for open barrels or containers.
Empty the pump, hose and fittings prior to removing the motor.
In case of counter-pressure, do not remove the motor or use a pump
with an inner tube lock.
Remove spilled liquid from the floor and dispose of it in an environ-
mentally sound manner.
Only use the pump for its intended purpose.
Never leave the pump unattended.
The pump has to be used in vertical position only (except for hori-
zontal versions).
Install the pump in a way which ensures that it cannot fall into the
container.
Only use the pump with a suitable hose.
Ensure that the hose is securely fixed to the hosetail.
Regularly check the hose and connections to ensure safe operation.
The pump should not be immersed deeper into the liquid than the
outlet connection.
Comply with the operating instructions of the motor (some three-
phase motors have their safety instructions contained with the ter-
minal box).
Do not grip three-phase motor on ventilator cap for carrying.
Never operate the pump dry.
We recommend the installation of device to protect the pump
against dry running such as a flow control, contact manometer,
differential pressure switch, level control or similar appropriate
devices.
Avoid the operation at closed suction side.
The pump should not be exposed to the weather.
Clean after each operation.
Never store the motor in areas in which corrosive vapours exist.