• with a copper pipe. The joints of this pipe must consist of unions with
mechanical seals.
• With seamless flexible stainless steel pipe. The length of this pipe must be
2 meters at most and the seals must comply with the standards. It is
advisable to apply the special adapter to the flexible pipe. This is easily
available from the shops and facilitates connection with the hose nipple
of the pressure governor on the bottle.
• With rubber hose pipe in compliance with standards. The diameter of this
hose pipe must be 8 mm and its length must be no less than 400 mm and
no more than 1500 mm. It must be firmly fixed to the hose nipple by
means of the safety clamp specified by standards.
At the connection end, verify the gasproof using a soap solution, never a flame.
ATTENTION: To avoid all risk, if the power cable becomes damaged, it must only be
replaced by the manufacturer, by an authorised service centre, or by a qualified
electrician.
WARNINGS:
Remember that the gas inlet union on the appliance is a 1/2" gas conic male type in
compliance with EN 10226 standards.
Installation of stainless steel pipe and rubber hose pipe must ensure that it is never able
to touch mobile parts of the built-in cabinet (eg. drawers). Furthermore, it must not pass
through compartments that could be used for storage purposes.
When using a rubber hose pipe, it is essential to comply with the following instructions:
38