Manual Settings - GYS GYSPOT ARCPULL 200 Mode D'emploi

Masquer les pouces Voir aussi pour GYSPOT ARCPULL 200:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
> Pregas
> 100ms
Postgas
500ms
Language
EN
Product reset
Info

MANUAL SETTINGS

Manual Settings
Start-up
> Q = 0
Push the Menu/Validate button
Synergic Settings
Push the return button
> Material
> Fe
Range of settings for the manual
Gas
ON
Electrode
Ring
mode
THK. elec.
1.5 mm
Arcing
-5 to 5 (default value 0)
Main Menu
Product reset
> Settings
Manual Mode
Penetration
10 to 60 A
Configuration
and cleaning
0 to 200 ms
:3 sec
Arc
0 to 200A*
Main Menu
to reset
0 to 500 ms
Configuration
Attachment
-5 to 5 (default value 0)
> Settings
> Pregas
> 100ms
Manual Mode
0 to 50 ms
Postgas
500ms
Configuration
Language
EN
Height
0.5 mm to 5 mm
Product reset
Info
CONFIGURATION
Configuration
Manual Settings
> Pregas
> 100ms
Postgas
500ms
Language
EN
Product reset
Info
Start-up
> Q = 0
Range of settings
Pregas
NoGas then from 0.2s to 3s
Manual Settings
Synergic Settings
Postgas
NoGas or from 0.2s to 3s
> Material
> Fe
Gas
ON
Language
FR, GB, DE, NL, ES, IT, RU
Electrode
Ring
Start-up
> Q = 0
THK. elec.
1.5 mm
Push the return button
Reset machine
Synergic Settings
Product reset
> Material
> Fe
Gas
ON
Electrode
Ring
THK. elec.
1.5 mm
:3 sec
to reset
Product reset
GYSPOT ARCPULL 200
Press the keys G+ and G- to browse the different values (arcing and attachment coeffi-
cients, duration, currents, height) of the drawn arc process (see chapter «Drawn arc wel-
ding process»).
Press the keys D+ and D- to modify the values (coefficients, duration, current, height).
to confirm the manual settings and return to the manual welding screen.
to ignore the settings and return to the Main Menu.
Comment
The default value is set to ensure optimal arcing and stop the arc
from breaking up when pulling the electrode while limiting the
short-circuit current.
Reducing the arcing increases the risk of the arc breaking up
Increasing the arcing forces an unnecessary high short-circuit
current.
Limited to 100A if product is connected to a 110Vac ±15% power
supply.
The default value is set to ensure optimal attachment of the elec-
trode onto the metal support.
Press the keys G+ and G- to move the left cursor (Pregas, Postgas, Language, Reset
machine, Info).
When the items Pregas, Postgas or Langue are highlighted, press the keys D+ and D- to
modify their value.
Comment
For a good gas protection when welding, it is recommended to set a
minimum pre-gas of 0.2s and a gas flow between 10 and 12L/min.
To weld using a gas coating, it is recommended to have a minimum
postgas setting of 0.2s.
to return to the Main Menu.
When the «Reset Machine» is selected from the Configuration menu, pressing menu/vali-
date
opens the reset machine sub-menu.
Press menu/validate
Push the return button
reset.
for 3 seconds to confirm product reset.
to return to the Configuration menu and cancel product
EN