10.4 IR200 Pir Motion Detector

Radio communication method .................................. FM
Frequency ................................................................ 868MHz
Radio range ............................................................. 200m
Batteries .................................................................. 2x 1.5V AA Alkaline
Batteries' life ............................................................ 2 years
Low battery indication .............................................. Signal to the control panel, panel will display
IR covering............................................................... 12m @ 2m above ground
Sensitive areas ........................................................ Far: 11 sectors, middle: 8 sectors, near: 5
Protections ............................................................... Anti-opening
Working temperature ............................................... -10°C ÷ +45°C
Supervision interval .................................................. 30-50 min.
Case material ........................................................... ABS707
Dimensions (l x h x w) in millimetres ........................ 120 x 74 x 55

10.5 EIR200 Pir external Motion Detector

Radio communication method .................................. FM
Frequency ................................................................ 868MHz
Radio range ............................................................. 200m
Batteries .................................................................. 2x 3.6V Lithium AA
Batteries' life ............................................................ 2 years
Low battery indication .............................................. Signal to the control panel
IR covering............................................................... 11m @ 2.3m above ground
Sensitive areas ........................................................ Upper- far: 10 sectors, middle:9 sectors, near:
Protections ............................................................... Anti-opening
Working temperature ............................................... -10°C ÷ +45°C
Supervision interval .................................................. 30-50 min.
Case material ........................................................... ABS978B
Dimensions (l x h x w) in millimetres ........................ 68 x 148 x 50

10.6 DC200 Door contact

Radio communication method .................................. FM
Frequency ................................................................ 868MHz
Radio range ............................................................. > 100m
Batteries .................................................................. 2 x Alkaline AAA
Batteries' life ............................................................ 2 years
Low battery indication .............................................. Signal to the control panel, panel will display
Detector ................................................................... Reed Switch
Auxiliary wire inputs ................................................. 1
Inputs connections ................................................... Dry Connect
Perimeter contacts connection cables max length .... 5m
Contact - magnet maximum distance ....................... 30mm
Protections ............................................................... Anti-removal, anti-opening
Working temperature ............................................... -10°C ÷ +45°C
Supervision interval .................................................. 30-50 min.
Case material ........................................................... ABS707
Dimensions (l x h x w) in millimetres ........................ 135 x 33 x 22