KOMFORT ZONE KIT
#KZK-158A
For use with the Callaway-40 #CLW-40
Direct Vent Gas Fireplace
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents.......................................................................................... 3
1.2 Suggested Configurations .............................................................. 4
1.3 Dimensions and Overview ............................................................. 5
1.4 Air Duct Run ......................................................................................... 6
2.0 FRAMING AND CLEARANCES ................................................7
2.1 Clearance to Sprinkler ...................................................................... 7
2.2 Framing.................................................................................................. 8
2.3 Minimum Shelf Requirements ...................................................... 9
3.0 FACING AND FINISHING .......................................................10
3.1 Non-combustible Requirements ................................................10
3.2 Combustible Finish ..........................................................................11
3.3 Hearth and Mantel Clearances ....................................................13
4.0 INSTALLATION .......................................................................14
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HUSSONG MANUFACTURING CO., INC.
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner's manual
completely before performing any procedures in
these instructions.
This optional convection duct kit redistributes the
warm air flow away from the fireplace opening to
a more desirable location using natural convection
without the use of a fan. The warm air flow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result
is much cooler wall temperatures above the fire-
place opening for locating televisions, artwork, etc.
Rev. 2, 11/19

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Kozy Heat Fireplaces KOMFORT ZONE KIT

  • Page 1: Table Des Matières

    KOMFORT ZONE KIT #KZK-158A For use with the Callaway-40 #CLW-40 HUSSONG MANUFACTURING CO., INC. Direct Vent Gas Fireplace INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. English and French installation manuals are available through your READ ALL THESE STEPS local dealer.
  • Page 3: Introduction

    (197mm) (4) takeo collars included Figure 1.1, #KZK-158A #KZK-410 (4) - 10’ x 5” (aluminum ex) listed to UL-181Class 0 Air Duct Figure 1.2, #KZK-410 Komfort Zone Kit #KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3...
  • Page 4: Suggested Configurations

    The (2) plenums and the (2) air grilles in this kit are required and must be installed. #KZK-158A Side Wall Outlet #KZK-158A Rear Wall Outlet Figure 1.3, #KZK-158A Suggested Configurations 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-158A R.2...
  • Page 5: Dimensions And Overview

    If you are mounting the plenum above the fireplace between 10’ to 20’ , you will need (2) #KZK-410 kit and #KZK-CPL coupler kit. Figure 1.5, KZK-158A Overview Komfort Zone Kit #KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5...
  • Page 6: Air Duct Run

    WHEN INSTALLING AIR DUCT PIPE MAINTAIN A MINIMUM 4" VERTICAL RISE FOR EVERY 12" HORIZONTAL RUN Minimum bend radius=5” (127mm) 4” (102mm) 12” (304mm) Figure 1.6, Minimum Vent Pipe Run 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-158A R.2...
  • Page 7: Framing And Clearances

    Please follow local building codes to determine what temperature setting is relevant for your installation. 60” (1524mm) 3” Ceiling (76mm) Sprinkler Head Figure 2.1, KZK-158A Clearance to Sprinkler Komfort Zone Kit #KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 7...
  • Page 8: Framing

    (1208mm) 74” Finishing Edge ½ (1880mm) ” (1435mm) ¼ ” (1200mm) ¼ ” (1200mm) 22” (559mm) Figure 2.4,CLW-40 Unit Wall Enclosure Rough Opening 8 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-158A R.2...
  • Page 9: Minimum Shelf Requirements

    7” (178mm) 18” (457mm) 18” 22” (457mm) (559mm) Figure 2.5, Minimum Shelf Requirements Komfort Zone Kit #KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 9...
  • Page 10: Facing And Finishing

    No Screws Allowed No Screws Allowed 13” ¾ ¾ ” ” (330mm) (95mm) 13” (95mm) (330mm) Figure 3.2, Minimum Non-combustible Finishing Dimensions Screw Locations 10 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-158A R.2...
  • Page 11: Combustible Finish

    ⁄ ” (200mm) NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE Figure 3.3, Drywall Finish and Combustible Material up to 1" Thick around Discharge Grille Komfort Zone Kit #KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 11...
  • Page 12 1” (25mm) thick may be installed over cement board Finishing Edge Fireplace Enclosure Floor Figure 3.4, KZK-158A Combustible Wall Finish with Surround 12 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-158A R.2...
  • Page 13: Hearth And Mantel Clearances

    ⁄ ” (676mm) Finishing Edge 14” (356mm) ⁄ 17” (432mm) ” (251mm) 20” (508mm) Figure 3.6, Hearth and Mantel Clearances for No Surround Komfort Zone Kit #KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 13...
  • Page 14: Installation

    (see previous pages). Fix the plenum to the framing using nails or screw Figure 4.4, Air Grille Screw Location through the top mounting bracket. 14 INSTALLATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-158A R.2...
  • Page 16 KIT KOMFORT ZONE nº KZK-158A Pour utiliser avec le foyer au gaz à évacuation HUSSONG MANUFACTURING CO., INC. directe Callaway-40 nº CLW-40 INSTALLATEUR : Laissez ce manuel avec l’appareil. PROPRIÉTAIRE : Conservez ce manuel pour le consulter. English and French installation manuals are available through your LISEZ TOUTES CES ÉTAPES local dealer.
  • Page 18: Introduction

    (4) - section de 10 pieds x 5 po conduit exible (aluminium) homolgué UL-181, Conduit d’air De Classe 0 Figure 1.2, Item no KZK-410 Kit Komfort Zone nº KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3...
  • Page 19: Configurations Suggérées

    1.2 Configurations suggérées KZK-158A sortie murale adjacent KZK-158A sortie murale arrière Figure 1.3, Configurations suggérées du KZK-158A 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-158A R.2...
  • Page 20: Dimensions Et Vue D'ensemble

    Si vous installez le plénum à plus de 10 pieds (3 m) et moins de 20 pieds (6 m) au-dessus du foyer, vous aurez besoin de deux (2) kits nº KZK-410 et du kit de coupleurs nº KZK-CPL. Figure 1.5, Vue d'ensemble du kit KZK-158A Kit Komfort Zone nº KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 5...
  • Page 21: Installation Des Conduit D'air

    À TOUS LES 12 PO (30 CM) DE COURSE HORIZONTALE Rayon de courbure minimal=5” (127mm) 4” (102mm) 12” (304mm) Figure 1.6, Installation de conduits d'air de longueur minimale 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-158A R.2...
  • Page 22: Encadrement Et Dégagements

    à votre installation. 60” (1524mm) 3” Tête de gicleur (76mm) au plafond Figure 2.1, Dégagement au gicleur du kit KZK Kit Komfort Zone nº KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 7...
  • Page 23: Encadrement

    (1208mm) 74” Bord de nition ½ (1880mm) ” (1435mm) ¼ ” (1200mm) ¼ ” (1200mm) 22” (559mm) Figure 2.4, Encadrement et dégagement 8 ENCADREMENT ET DÉGAGEMENTS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-158A R.2...
  • Page 24: Dimensions Minimales D'installation Et Exigences Avec Étagère

    à une étagère murale ou une tablette encastrée. 7” (178mm) 18” (457mm) 18” 22” (457mm) (559mm) Figure 2.5, Requis d'une tablette d'étagère Kit Komfort Zone nº KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 9...
  • Page 25: Façade Et Finition

    ¾ ” ” (330mm) (95mm) 13” (95mm) (330mm) Figure 3.2, Emplacements de vis permis (pour matériaux incombustibles de finition de dimensions minimales 10 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-158A R.2...
  • Page 26: Matériaux De Finition Murale Combustibles

    ” (200mm) ⁄ ” (200mm) Cette installation n'est pas autorisée pour une tablette encastrée Figure 3.3, Finition de la grille d'évacuation d'air Kit Komfort Zone nº KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 11...
  • Page 27 Bord de nition du foyer Plancher d’enceinte du foyer Figure 3.4, Matériaux de finition murale combustibles avec le KZK-158A 12 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-158A R.2...
  • Page 28: Dégagements De L'âtre Et Du Manteau

    14” (356mm) 17” (432mm) ⁄ ” (251mm) 20” (508mm) Figure 3.6, Dégagements de l’âtre et du manteau pour une installation sans contour Kit Komfort Zone nº KZK-158A R.2 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 13...
  • Page 29: Installation

    à l’encadrement, avec des vis (ou clous) traversant la bride de fixation supérieure. NOTE: Les brides de fixation ne sont pas conçues pour Figure 4.4, Installation de la grille d'air 14 INSTALLATION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-158A R.2...