GYS GYSPOT PTI GENIUS Manuel D'utilisation page 53

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SPOT COUNT
If the caps are not changed after the warning message is displayed and the count is simply reset, they can deteriorate and have a negative
impact on the quality of the weld.
RECORDING FEATURES
The Identification mode is optional and can be activated using the «settings» menu.
If the identification mode is switched off, il suffit de saisir un nom de rapport et de l'activer pour mémoriser les points de soudure effectués.
The log allows to store the parameters of the spots made using the clamp. It is available in all the modes by pressing the 2 buttons
The user program is available in all modes by pressing the
Report (log)
The log created contains: an ID entered by the user, as well as for each spot performed, the tool and arm used, the machine settings (power and
pressure). It also contains the following possible error messages that may have occurred during its recording: I LOW, P LOW, PB CAPS.
The ID is entered using the 4 keys +, -
without deleting the previous ones.
The
button is used to retrieve a previously saved report and read it back on the screen.
The current recording must be stopped by pressing the
report view mode.
To delete the contents of a report, you must
display it on the screen using the button
GYSPOT PTI GENIUS
A spot count tool keeps count of the different spot weld done using the same cap. If there is no
problem during the welding, the following message is displayed.
The count is displayed at the top left corner of the screen. Press the button
reset the count after changing the caps.
The machine counts the number of points achieved with each arm independently. A warning
message appears on the screen when the limit of the points made by the headings is reached. The
message remains displayed after each point until the counter is reset.
and
buttons.
Saving a report allows you to retrieve the data of a series of spot made with using the clamp, and to
save them on the memory card so that they can be retrieved from a PC for example. GYS provides
a software called GYSPOT to read the SD card and edit the logs on a PC. This GYSPOT software is
stored on the SD card as well as the user manual.
By default, this feature is disabled when the machine is switched on. Pressing the recording button
(on/off) and the «mode» button starts recording the report in the selected log. Pressing the record
button again (on/off) stops the current recording.
or
. When entering an identifier already in use, the machine will record the new points in succession,
button before it can be displayed on the screen. The
Then press the
button.
The following message appears on the
.
screen.
button is used to exit the
When the triangle is displayed, a second press
on the
button erases the content of the
report displayed.
The triangle disappears from the screen auto-
matically after 3 seconds.
EN
for 2 seconds to
and
.
53

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pot bp genius 400 v

Table des Matières