Decrement the output voltage on output <n> by the delta voltage value and verify that the voltage
is within ±3 counts or 5% of the target value. If the value of the output voltage is outside the range
for the specified output the value is set to the minimum value allowed, no error is generated.
DECV<n>
Sequential command
Operation complete message generated immediately after execution.
This command is identical to DECV<n>V above except that no verification of the output voltage is
performed, thus saving the possible 500ms required to read back the output voltage. This is
useful when it is known that the slew time will be short or during constant current operation.
INCI<n>
Sequential command
Operation complete message generated immediately after execution.
Increment the set current of output <n> by the delta current value. If the value of the set cuttent is
outside the range for the specified output the value is set to the maximum value allowed, no error
is generated.
DECI<n>
Sequential command
Operation complete message generated immediately after execution.
Decrement the set current of output <n> by the delta current value. If the value of the set cuttent
is outside the range for the specified output the value is set to the minimum value allowed, no
error is generated.
OP<n> <nrf>
Sequential command
Operation complete message generated immediately after execution.
Sets the output status of output <n> ON or OFF. If the value of <nrf>, after rounding, is 0 the
output status will be set to OFF if 1 the output status will be ON. If the value of <nrf> is not 0 or 1
execution error 200 (Value out of range) will be generated.
OPALL <nrf>
Sequential command
Operation complete message generated immediately after execution.
Sets the output status of all outputs ON or OFF. If the value of <nrf>, after rounding, is 0 the
output status will be set to OFF if 1 the output status will be ON. If the value of <nrf> is not 0 or 1
execution error 200 (Value out of range) will be generated.