DEUTSCH
2.5

Master-Slave-Modul

Technische Daten
Nutzungsbeschränkung: Europa
Nennspannung: max. 250 Vac
Nennstrom, max. Betriebsstrom:
I
+ I
(cosϕ = 1): max. 16 A
MASTER
SLAVE
I
: 16 A–I
MASTER
SLAVE
I
: 16 A–I
SLAVE
MASTER
I
(cosϕ = 0,4): max. 8 A
SLAVE (max)
(I
< 8 A)
MASTER
Maximale Schaltleistung:
cosϕ = 1: 4 000 VA ∼,
cosϕ = 0,4: 2 000 VA ∼
Leistungsaufnahme (Leerlauf):
< 2 W (230 V)
Einschaltstrom: 55 mA ± 5 %
(Werkeinstellung)
Ausschaltstrom: 43 mA ± 5 %
(Werkeinstellung)
Einschaltverzögerung: 550 ms
(I
> 1,15 x I
MASTER
Ausschaltverzögerung: 550 ms
(I
< 0,7 x I
MASTER
Einschaltstrom-Einstellbereich:
20...200 mA
Temperaturbereich: 0...40 °C
Relative Luftfeuchtigkeit: < 90 %
Funktion
Nach Einschalten des Master-Gerätes
an der schwarzen Steckdose schalten
die Slave-Steckdosen mit einer halben
Sekunde Verzögerung.
Sind die Slave-Geräte eingeschaltet,
können sie durch das Einschalten des
Masters in Betrieb genommen werden.
Durch Ausschalten des Master-Gerätes
werden auch alle Slave-Geräte vom
Netz getrennt.
Schaltschwelle einstellen
Schalten die Slave-Geräte nach Inbetrieb-
nahme des Masters nicht ein, Schwellwert
herabsetzen.
Mastergerät einschalten und sicher-
stellen, dass die Slave-Geräte betriebs-
bereit, d. h. eingeschaltet sind.
Einstellschraube langsam nach
rechts drehen, bis das Relais der
Steckdosenleiste schaltet und die Slave-
Geräte mit Strom versorgt.
Gegenprobe: Master-Gerät ausschalten.
Die Slave-Geräte müssen selbsttätig
ausschalten.
Schalten die Slave-Geräte nach dem
Ausschalten des Masters nicht aus:
Schwellwert erhöhen.
Master-Gerät ein- und, nachdem die
Slave-Geräte alle aktiviert sind, wieder
ausschalten.
Einstellschraube langsam nach
links drehen, bis das Relais der
Steckdosenleiste abschaltet und die
Slave-Geräte stromlos sind.
18
Technical description
ENGLISH

Master-slave module

Technical data
): ± 20 % (230 V)
EINSCHALT
): ± 20 % (230 V)
AUSSCHALT
Function
Setting the switching threshold
If the slave units do not switch on after the
master has been switched on: Reduce the
threshold.
Usage restriction: Europe
Nominal voltage: max. 250 Vac
Nominal current, Max. operating current:
I
+ I
(cosϕ = 1): max. 16 A
MASTER
SLAVE
I
: 16 A–I
MASTER
SLAVE
I
: 16 A–I
SLAVE
MASTER
I
(cosϕ = 0.4): max. 8 A
SLAVE (max)
(I
< 8 A)
MASTER
Max. contact rating:
cosϕ = 1: 4 000 VA ∼,
cosϕ = 0.4: 2 000 VA ∼
Power consumption (idle): < 2 W (230 V)
Switch-on current: 55 mA ± 5 %
(factory setting)
Switch-off current: 43 mA ± 5 %
(factory setting)
Switch-on delay: 550 ms
(I
> 1.15 x I
): ± 20 % (230 V)
MASTER
SWITCH-ON
Switch-off delay: 550 ms
(I
< 0.7 x I
): ± 20 % (230 V)
MASTER
SWITCH-OFF
Switch-on current setting range:
20...200 mA
Temperature range: 0...40 °C
Relative humidity: < 90 %
After the master unit has been switched
on (on the black socket) the slave sockets
switch on with a half second delay.
Once the slave units have been switched
on they are ready for use by switching on
the master.
If the master unit is switched off, all slave
units are also disconnected from the
mains.
Switch on the master unit and ensure
that the slave units are in standby mode,
i. e. switched on.
Slowly turn the adjustment screw
clockwise until the relay on the socket
strip switches on and power is supplied to
the slave units.
Reverse test: Switch off master unit.
The slave units must switch off auto-
matically.
If the slave units do not switch off once
the master has been switched off:
Increase the threshold.
Switch master unit on, and once the slave
units have all been activated, switch it
back off.
Slowly turn the adjustment screw anti-
clockwise until the relay on the socket
strip switches off and no further current
is supplied to the slave units.
Description technique
FRANÇAIS

Module Master Slave

Caractéristiques techniques
Restriction d'usage : Europe
Tension nominale : max. 250 Vac
Intensité nominale, courant de service max. :
I
+ I
(cosϕ = 1) : max. 16 A
MASTER
SLAVE
I
: 16 A–I
MASTER
SLAVE
I
: 16 A–I
SLAVE
MASTER
I
(cosϕ = 0,4) : max. 8 A
SLAVE (max)
(I
< 8 A)
MASTER
Puissance d'interruption maximale :
cosϕ = 1 : 4 000 VA ∼,
cosϕ = 0,4 : 2 000 VA ∼
Consommation (marche à vide) :
< 2 W (230 V)
Courant de démarrage : 55 mA ± 5 %
(réglage en usine)
Courant de coupure :43 mA ± 5 %
(réglage en usine)
Temporisation d'enclenchement : 550 ms
(I
>1,15 x I
) : ± 20 % (230 V)
MASTER
ENCLENCHEMENT
Temporisation de mise hors servie : 550 ms
(I
<0,7 x I
) : ± 20 % (230 V)
MASTER
MISE HORS SERVICE
Plage de réglage du courant de fermeture :
20...200 mA
Plage de températures : 0...40 °C
Humidité de l'air relative : < 90 %
Fonction
Après mise en marche de l'appareil Master
(au niveau de la prise noire), les prises
Slave commutent au bout d'une demi
seconde.
Si les appareils Slave sont enclenchés, ils
peuvent être mis en service par l'enclen-
chement du Master.
En éteignant l'appareil Master, tous les
appareils Slave sont également coupés du
réseau.
Régler le seuil de commutation
Si les appareils Slave ne se mettent pas
en marche après la mise en service du
Master : abaisser le seuil de commutation.
Allumer l'appareil Master et s'assurer
que les appareils Slave sont prêts à fonc-
tionner, c'est-à-dire qu'ils sont allumés.
Tourner le bouton de réglage lentement
vers la droite jusqu'à ce que le relais de la
réglette de prises commute et alimente les
appareils Slave en courant.
Contre-test : éteindre l'appareil Master.
Les appareils Slave doivent s'arrêter
automatiquement.
Si les appareils Slave ne s'éteignent
pas après la coupure du Master :
relever le seuil de commutation.
Mettre en marche l'appareil Master et
l'éteindre lorsque les appareils Slave sont
activés.
Tourner le bouton de réglage lentement
vers la gauche jusqu'à ce que le relais de la
réglette de prise coupe et n'alimente plus
les appareils Slave en courant.