b. The temperature set-point (Set temperature) can be adjusted from 16°C to 31°C with 1°C variations
thanks to B4/B5 or SW3/SW4 and the respective value appears on the display.
c. Three minutes (maximum) after the activation of this operating mode the compressor starts and the
ap-pliance starts to distribute cold air.
3.6 - VENTILATION MODE (FAN)
a. When this operating mode is used the appliance has no effect on the temperature or humidity of the
environment, it merely circulates the air.
b. This mode can be selected by pressing B7 or SW2 until when the ventilation LED
(S5) is activated on the control panel display.
c. In this operating mode, the internal fan is always on and it is possible to select the desired speed through
the keys B6 or SW6; the respective LEDs "High" (S1) or "Low" (S2) light up.
3.7 - DEHUMIDIFICATION MODE (DRY)
a. This mode can be selected by pressing B7 or SW2 until when the dehumidification LED
(S4) is activated on the control panel display.
b. In DRY mode, it is not possible to select the fan speed or to adjust temperature.
The fan motor works at low speed.
c. Keep doors and windows closed to achieve the best dehumidifying effect.
Do not place the air outlet pipe out of a window.
d. Connect the condensation discharge pipe (paragraph 2.5.a)
3.8 - SLEEP MODE
a. This mode can be selected by pressing B3 or SW7 until when the LED (S7) switches on.
b. In this mode, the appliance enters energy conservation mode and works silently, autonomously decreasing
the fan speed.
3.9 - TIMER MODE
This mode can be used to activate a switching on/off timer of the appliance.
To activate the appliance SWITCHING ON timer, work as follows:
a. With the appliance in stand-by mode (with the power plug connected), press the keys B2 or SW5.
b. When the LED S6 flashes, set the desired time value through the keys B4/B5 or SW3/SW4
(0h (Timer off) ---> 1h ---> 2h ---> .. 24h ---> 23h ---> 22h ---> .. 0h (Timer off) ---> ..).
c. The LED S6 remains steady on.
d. The appliance will switch on automatically when it reaches the previously set time.
To activate the appliance SWITCHING OFF timer, work as follows:
a. With the appliance switched on (LED S8 active), press the keys B2 or SW5.
b. When the LED S6 flashes, set the desired time value through the keys B4/B5 or SW3/SW4
(0h (Timer off) ---> 1h ---> 2h ---> .. 24h ---> 23h ---> 22h ---> .. 0h (Timer off) ---> ..).
c. The LED S6 remains steady on.
d. The appliance will switch off automatically when it reaches the previously set time.
3.10 - NO FROST FUNCTION
In "Cooling", "Dehumidification" or "Sleep" mode, if the drainage tube temperature is too low, the machine
automatically enters protection status; when temperature raises, the appliance returns to normal operation.
EN - 23